![Endress+Hauser Proline Promass 40E Technical Information Download Page 13](http://html1.mh-extra.com/html/endress-hauser/proline-promass-40e/proline-promass-40e_technical-information_2408103013.webp)
Proline Promass 40E
Hauser
13
Electromagnetic
compatibility (EMC)
As per IEC/EN 61326 and NAMUR recommendation NE 21
Process
Fluid temperature range
Sensor
–40 to +140 °C (–40 to +284 °F)
Medium density
0 to 5000 kg/m
3
(0 to 312 lb/ft
3
)
Secondary containment
pressure rating
The sensor housing is filled with dry nitrogen and protects the electronics and mechanics inside.
The secondary containment does not have pressure vessel classification.
Reference value for the pressure loading capacity of the sensor housing: 16 bar (232 psi).
Pressure-temperature
ratings
The following pressure-temperature ratings refer to the entire device and not just the process
connection.
Flange connection according to EN 1092-1 (DIN 2501)
Flange material: 1.4404 (F316/F316L)
A0020972-EN
300
[°F]
350
250
200
150
100
50
0
-50
[°C]
200
150
100
50
0
-50
400
0
10
20
30
40
50
70
60
80
90
[bar]
[psi]
200
400
600
800
0
1000
1200
100
1400
PN 40
PN 100
PN 63