![Endress+Hauser Proline Promag Operating Instructions Manual Download Page 18](http://html1.mh-extra.com/html/endress-hauser/proline-promag/proline-promag_operating-instructions-manual_2407216018.webp)
Installation
Proline Promag
18
Hauser
Adapters
100
10
0.5
d / D
[mbar]
0.6
0.7
0.8
0.9
1 m/s
2 m/s
3 m/s
4 m/s
5 m/s
6 m/s
7 m/s
8 m/s
1
D
d
max. 8°
A0029002
5.1.3
Special mounting instructions
Promag 200, 400
Display protection
‣
To ensure that the optional display guard can be easily opened, maintain the following
minimum head clearance: 350 mm (13,8 in)
Promag L 400
Temporary immersion in water
A remote version with IP67 protection, Type 6 is optionally available for temporary immersion
in water for up to 168 hours at ≤ 3 m (10 ft) or in exceptional cases for use for up to 48 hours
at ≤ 10 m (30 ft).
Compared with the standard degree of protection IP67, Type 4X enclosure, the version IP67,
Type 6 enclosure has been designed to withstand short-term or temporary flooding.