L
CAUTION
Risk of damaging the magnetic coil
‣
If transporting by forklift, do not lift the sensor by the metal casing.
‣
This would buckle the casing and damage the internal magnetic coils.
A0029319
5
Installation
5.1
Installation conditions
5.1.1
Mounting position
Mounting location
h
A0029343
h ≥ 2 × DN
Installation in down pipes
Install a siphon with a vent valve downstream of the sensor in down pipes whose length h ≥
5 m (16,4 ft). This precaution is to avoid low pressure and the consequent risk of damage to
the measuring tube. This measure also prevents the system losing prime.