Technical data
Proline Promag W 400 HART
154
Hauser
Web server
Plain text display
With information on cause and remedial measures
Light emitting diodes (LED)
Status information
Status indicated by various light emitting diodes
The following information is displayed depending on the device version:
• Supply voltage active
• Data transmission active
• Device alarm/error has occurred
Diagnostic information via light emitting diodes
Low flow cut off
The switch points for low flow cut off are user-selectable.
Galvanic isolation
The following connections are galvanically isolated from each other:
• Inputs
• Outputs
• Power supply
Protocol-specific data
HART
• For information on the device description files
• For information on the dynamic variables and measured variables (HART device
16.5 Power supply
Terminal assignment
Supply voltage
Transmitter
Order code for "Power supply"
terminal voltage
Frequency range
Option
L
DC 24 V
±25%
–
AC 24 V
±25%
50/60 Hz, ±4 Hz
AC 100 to 240 V
–15 to +10%
50/60 Hz, ±4 Hz
Power consumption
Order code for "Output"
Maximum power consumption
Option
H
: 4-20mA HART, pulse/frequency/switch
output, switch output
30 VA/8 W
Option
I
: 4-20mA HART, 2 x pulse/frequency/switch
output, status input
30 VA/8 W
Option
J
: 4-20mA HART, certified pulse output, pulse/
frequency/switch output, status input
30 VA/8 W
Summary of Contents for Proline Promag W 400 HART
Page 197: ......
Page 198: ...www addresses endress com...