Proline Promag L 800
Electrical connection
Hauser
39
7.4.2 Inserting and connecting the batteries
#
Warning!
Risk of electric shock! Switch off the power supply before opening the device.
"
Caution!
Can damage the electronic of the device!
Only use batteries provided by Hauser.
1.
Open the housing cover.
– Release the four screws with a Phillips head screwdriver.
– Lift the housing cover slightly and tip it to the left.
Two flexible fasteners secure the housing cover to the housing.
2.
Remove the battery cover.
– Release the securing screw with a Phillips head screwdriver.
– Turn the battery cover in a slightly clockwise direction to remove it (two guides which
hold the battery cover in position are located on the right-hand side).
3.
Insert the batteries.
Place the batteries into the compartment. In doing so, route the battery cables in the
direction of the cable inlet in the battery cover
24.
If not all the batteries are inserted, the partition plate can be used to prevent any
inserted batteries from becoming dislodged.
Configuration 6
Configuration of batteries
Connectors
Number of
batteries
Battery usage
A0017132
B 1
1
Backup power supply for the measuring device
B 2
–
Power supply for the measuring device
B 3
3
Power supply for the GSM/GPRS modem
Powered via external power
supply
Power supply for the measuring device
"Power Supply" order feature: 5L8B**–**KP*********
B
1
B
1
B
2
B
3
B
3