Proline Promag H 300
Hauser
19
Dynamic variables
Read out the dynamic variables: HART command 3
The measured variables can be freely assigned to the dynamic variables.
Measured variables for PV (primary dynamic variable)
• Off
• Volume flow
• Mass flow
• Corrected volume flow
• Flow velocity
• Corrected conductivity
• Temperature
• Electronic temperature
Measured variables for SV, TV, QV (secondary, tertiary and quaternary
dynamic variable)
• Volume flow
• Mass flow
• Corrected volume flow
• Flow velocity
• Corrected conductivity
• Temperature
• Electronic temperature
• Totalizer 1
• Totalizer 2
• Totalizer 3
Device variables
Read out the device variables: HART command 9
The device variables are permanently assigned.
A maximum of 8 device variables can be transmitted:
• 0 = volume flow
• 1 = mass flow
• 2 = corrected volume flow
• 3 = flow velocity
• 4 = conductivity
• 5 = corrected conductivity
• 6 = temperature
• 7 = electronic temperature
• 8 = totalizer 1
• 9 = totalizer 2
• 10 = totalizer 3
PROFIBUS PA
Manufacturer ID
0x11
Ident number
0x156C
Profile version
3.02
Device description files (GSD,
DTM, DD)
Information and files under:
•
•
www.profibus.org
Summary of Contents for Proline Promag H 300
Page 96: ...www addresses endress com ...