Promag 50/53 W
Hauser
Nominal Diameter
1
7H
28”
7F
30”, AWWA
8H
32”
9H
36”
T0
40”
V0
42”, AWWA
T2
48”
V3
54”, AWWA
V5
60”, AWWA
V6
66”, AWWA
T8
72”
V9
78”, AWWA
2
Liner
H
Hard rubber
U
Polyurethane
3
Process Connection
L
Class 150 ANSI B16.5 carbon steel A105 flanges
M
Class 300 ANSI B16.5 carbon steel A105 flanges
P
Class D AWWA carbon steel C207 flanges
R
Class 150 ANSI B16.5, 316L SS flanges
S
Class 300 ANSI B16.5, 316L SS flanges (not for 8” and
larger sensors)
9
Other
4
Electrodes / Material
0
Measuring, reference and EPD electrodes / 316L SS
1
Measuring, reference and EPD electrodes / Alloy C-22
2
Measuring, reference and EPD electrodes / tantalum
7
Measuring electrode, exchangeable / 316L SS
(for hard rubber liner only, 14” and larger sensors, no EPD or
reference electrodes, for safe areas only)
G
Measuring, reference and EPD electrodes, bullet nose / 316L SS
H
Measuring, reference and EPD electrodes, bullet nose / Alloy C-22
9
Other
5
Calibration
B
3-point calibration, 0.2%
E
SCS/A2LA 3-point 0.2% calibration (ISO/IEC 17025) with certificate
traceable according to ISO 9000 (specify flow range)
9
Other
6
Certificates
1
Standard, no certificate
2
3.1B material certificate for pipe and flanges
3
2.3 pressure test certificate (1.5 x PN, 3 minutes) for sensors
up to 12” only
4
3.1B material and 2.3 pressure test certificate for sensors
up to 12” only
5
CRN approval for ANSI flanges only
8
CRN approval, 3.1B material certificate and 2.3 pressure test
certificate (1.5 x PN) for ANSI flanges only
7
Approvals
A
For use in non-hazardous areas
N
FM explosion proof Class I, Div. 1 / CSA Class I, Div. 1 (only for
aluminum field housing, compact version, not for 12” and larger
sensors)
R
FM non-incendive Class I, Div. 2 / CSA Class I, Div. 2
8
Protection type / Version
A
NEMA 4X / compact, aluminum field housing
C
NEMA 4X / remote wall mounted housing (only for approvals A or R)
K
NEMA 6P remote, wall mounted housing (only for approvals A or R)
N
NEMA 6P / remote aluminum field housing, nonhazardous, not for
12” and larger sensors
1
-40°F (-40°C) ambient temperature, NEMA 4X / compact aluminum
housing for transmitter (only for approvals A or R)
3
-40°F (-40°C) ambient temperature, NEMA 4X / compact SS housing
for transmitter (only for approvals A or R)
5
-40°F (-40°C) ambient temperature, NEMA 4X / remote wall mount
housing for transmitter (only for approvals A or R)
9
Other
Promag 53 W -
Promag 53 W Electromagnetic Flowmeter, 28” to 78”
1 2 3 4 5 6 7 8 9 10 11 12 13
9
Cable for Remote Version
0
Without cable
1
15 foot coil and signal cable
2
30 foot coil and signal cable
5
Coil and signal cable, specify length in feet, maximum 650 feet,
depending on conductivity of process material
9
Other
10
Cable Entries
B
1/2” NPT
L
Fieldbus connector (Outputs / Inputs H or K, and Approval A only)
X
Sensor only, without cable (compact version only)
9
Other
11
Display / Power Supply / Operation
7
85 to 260 VAC, without display, remote configuration only (not for
wall mount or SS housing)
8
20 to 55 VAC / 16 to 62 VDC, without display, remote configuration
only (not for wall mount or SS housing)
A
85 to 260 VAC, with display, touch control operation (language: EN,
ES, FR, IT, NL, PT, DE)
B
20 to 55 VAC / 16 to 62 VDC, with display, touch control operation
(language: EN, ES, FR, IT, NL, PT, DE)
X
Sensor only (without transmitter, only available up to 8”)
9
Other
12
Software
A
Standard
C
ECC electrode cleaning circuit (only for Approvals A or R)
X
Sensor only
13
Outputs / Inputs
A
Current / HART, frequency
B
Current / HART, frequency and 2 relays
C
Current / HART, frequency, 2 relays (flexible module)
D
Current / HART, frequency, relay, and status input (flexible module)
F
PROFIBUS PA IS (only for Approval N)
G
FOUNDATION fieldbus IS (only for Approval N)
H
PROFIBUS-PA (only for Approvals A or R)
J
PROFIBUS-DP
K
FOUNDATION fieldbus
L
Current / HART, 2 relays and status input/output (flexible module)
M
Current / HART, 2 frequency, status input/output (flexible module)
S
Current / HART (active), frequency; IS(only for Approval N)
T
Current / HART (passive), frequency; IS (only for Approval N)
2
Current / HART, frequency, current, relay (flexible module)
4
Current / HART, frequency, current input, relay (flexible module)
5
Current / HART, frequency, current input, status input (flexible module)
X
Sensor only
29