Endress+Hauser Omnigrad M TR13 Technical Information Download Page 27

Summary of Contents for Omnigrad M TR13

Page 1: ...the following outputs and communication protocols Analog output 4 to 20 mA HART PROFIBUS PA FOUNDATION Fieldbus Your benefits High degree of flexibility thanks to modular design with standard termina...

Page 2: ...aller sizes and better vibration resistance A relatively low principle based deviation of the resistance temperature characteristic from the standard characteristic of IEC 60751 can frequently be obse...

Page 3: ...ll international power grids More information on this can be found in the Technical Information see Documentation Design E 1 2 3 4 5 6 6a 6b IL IL L 10 mm 0 4 in 7 A0010444 2 Thermometer design 1 Inse...

Page 4: ...rmitted flow velocity are illustrated by the figure below Occasionally the pressure loading capacity of the process connection can be considerably lower The maximum allowable process pressure for a sp...

Page 5: ...he thermowell diminishes with increasing immersion length exposed to the stream of the fluid Detailed information may be taken from the figures below 100 200 300 400 500 v m s A 100 200 300 400 500 v...

Page 6: ...results in C must be multiplied by a factor of 1 8 Permissible deviation limits of thermoelectric voltages from the standard characteristic for thermocouples as per IEC 60584 or ASTM E230 ANSI MC96 1...

Page 7: ...1 s not available 55 s 12 mm 0 47 in t50 not available 11 s 38 s t90 not available 37 s 125 s Thermo meter type Diameter t x Grounded Ungrounded Reduced tip Tapered tip Straight tip Reduced tip Tapere...

Page 8: ...ulation resistance according to IEC 1515 between terminals and sheath material with a test voltage of 500 V DC 1 G at 20 C 5 M at 500 C Dielectric strength Tested at a room temperature for 5 s 6 1000...

Page 9: ...AISI 316L 1 4404 1 4435 X2CrNiMo17 12 2 X2CrNiMo18 14 3 650 C 1202 F 1 Austenitic stainless steel High corrosion resistance in general Particularly high corrosion resistance in chlorine based and acid...

Page 10: ...y and easily at a PC Endress Hauser offers free configuration software which can be downloaded from the Endress Hauser Website More information can be found in the Technical Information HART programma...

Page 11: ...on TA30A Specification 107 5 4 23 68 5 2 7 28 1 1 78 3 1 15 5 0 6 A0009820 Available with one or two cable entries Protection class IP66 68 NEMA Type 4x encl Temperature 50 to 150 C 58 to 302 F withou...

Page 12: ...rt Head color blue RAL 5012 Cap color gray RAL 7035 Weight 390 g 13 75 oz Ground terminal internal and external With 3 A symbol TA30P Specification 83 3 3 114 4 5 11 0 43 68 2 7 41 5 1 63 A0012930 Pro...

Page 13: ...ptional display Protection class IP66 IP67 Max temperature 70 C 158 F Material 316L 1 4404 stainless steel rubber seal under the cover hygienic design 4 digits 7 segments LC display loop powered with...

Page 14: ...40 to 221 F Design All dimensions in mm in M4x1 6 0 24 L E 10 0 4 10 0 4 75 3 33 1 3 42 1 65 33 1 3 42 1 65 X ID ID 1 2 3 IL X 5 0 2 12 0 47 4 33 1 3 44 1 73 L 0 5 0 02 0 5 0 02 12x11 5 A0010446 5 Dim...

Page 15: ...12 in R Reduced L 50 mm 1 97 in 1 3 mm 0 12 in S Straight 6 mm 0 24 in T Tapered L 70 mm 2 75 in 1 3 mm 0 12 in W Tapered DIN43772 3G L 90 mm 3 54 in 1 6 mm 0 24 in 1 not with material Hastelloy C276...

Page 16: ...nce 60g Measuring range accuracy class with temperature range 200 to 600 C cl A 200 to 600 C 200 to 600 C cl AA 0 to 250 C 50 to 400 C cl A 50 to 250 C 50 to 400 C cl AA 0 to 150 C 50 to 500 C cl A 30...

Page 17: ...tion PVDF PTFE Tantalum thermowell an additional jacket with a disc on the upper end will be used The standard surface finish of the coupling side of flanges ranges from 3 2 to 6 4 m Ra Other types of...

Page 18: ...ual input 1 2 7 6 5 4 3 1 2 7 6 5 4 3 Sensor input 2 Sensor input 1 RTD and 3 wire 4 RTD 3 wire Bus connection and supply voltage Display connection red white red red red white white black black yello...

Page 19: ...ter TMT8x dual input 6 4 1 2 Power supply head transmitter and analog output 4 20 mA or bus connection A0012698 EN 1 2 7 6 5 4 3 1 2 7 6 5 4 3 Sensor input 2 Sensor input 1 Bus connection and supply v...

Page 20: ...ing into a pipe then the immersion length should be at least half of the pipe diameter A further solution could be an angled tilted installation see C and D When determining the immersion length all t...

Page 21: ...rminal head This temperature must remain within the limit values defined in the Operating conditions section 10 20 30 T in K 0 100 125 150 175 200 75 mm 400 C 752 F 220 C 428 F 225 250 570 C 1060 F 3...

Page 22: ...with the specifications in DIN 43772 With regard to thermowells with tapered or reduced tips that do not comply with this standard these are tested using the pressure of corresponding straight thermo...

Page 23: ...grated into field devices and existing infrastructures offers data protection and transmission safety and can be operated in parallel with other wireless networks with minimum cabling complexity For d...

Page 24: ...endress com lifecyclemanagement On CD ROM for local PC installation FieldCare FDT based plant asset management tool from Endress Hauser It can configure all smart field units in your system and helps...

Page 25: ...n Thermocouple insert Omniset TPC100 TI278t 02 en iTHERM TS111 Insert for installation in thermometers TI01014T 09 en Thermowell and thermowell oversheats Thermowell for temperature sensors Omnigrad M...

Page 26: ......

Page 27: ......

Page 28: ...www addresses endress com...

Reviews: