Omnigrad M TR13, TC13
12
TA30D
Specification
107.5 (4.23)
110 (4.3)
28
(1.1) 78 (3.1)
15.5 (0.6)
A0009822
• Available with one or two cable entries
• Protection class: IP66/68 (NEMA Type 4x encl.)
• Temperature: –50 to +150 °C (–58 to +302 °F) without cable
gland
• Material: aluminum, polyester powder coated
Seals: silicone
• Threaded cable entry: G ½", ½" NPT and M20x1.5
• Protection armature connection: M24x1.5
• Two head transmitters can be mounted. In the standard
version, one transmitter is mounted in the terminal head
cover and an additional terminal block is installed directly
on the insert.
• Head color: blue, RAL 5012
• Cap color: gray, RAL 7035
• Weight: 390 g (13.75 oz)
• Ground terminal, internal and external
• With 3-A
®
symbol
TA30P
Specification
!83
(3.3)
114 (4.5)
11
(0.43)
68 (2.7)
41.5 (1.63)
A0012930
• Protection class: IP65
• Max. temperature: –40 to +120 °C (–40 to +248 °F)
• Material: polyamide (PA), antistatic
Seals: silicone
• Threaded cable entry: M20x1.5
• Protection armature connection: M24x1.5
• Head and cap color: black
• Weight: 135 g (4.8 oz)
• Types of protection for use in hazardous locations: Intrinsic
Safety (G Ex ia)
• Ground terminal: only internal via auxiliary clamp
TA20B
Specification
116 (6.54)
25 (1)
84 (3.3)
73 (2.87)
A0008663
• Protection class: IP65
• Max. temperature: 80 ˚C (176 ˚F)
• Material: polyamide (PA)
• Cable entry: M20x1.5
• Head and cap color: black
• Weight: 80 g (2.82 oz)
• 3-A
®
marked