![Endress+Hauser nivocompact FTC 831 Installation And Operating Manual Download Page 14](http://html1.mh-extra.com/html/endress-hauser/nivocompact-ftc-831/nivocompact-ftc-831_installation-and-operating-manual_2408451014.webp)
Rotating the Housing
The housing can be rotated if the cable gland is facing in the wrong
direction after the Nivocompact has been securely screwed in:
Loosening
•
Unscrew and remove the housing cover.
In the housing are 2 four-pole connections which are required if the cable
needs to be shortened. These should be kept in a safe place.
•
Loosen the central screw in the electronic insert.
•
Remove the plug-in electronic insert from the housing using the handle.
•
Slightly loosen the 3 screws in the housing, see Fig. 7.
Rotating
•
The housing can now be rotated through 360°.
Tightening
•
Tighten up the 3 screws in the housing so that the housing is well sealed
at the hexagonal nut.
•
Insert the electronic insert in the plug.
•
Securely tighten the central mounting screw
while making sure that the cable gland remains free.
Fig. 7
Loosening and rotating the housing.
Fig. 8
Securing the electronic insert.