5.10.4 Cone roof tank with seal pot PVC
950 (37.4)
440
(17.32)
250 (9.84)
2000 - 3000
(78.74 - 118.11)
300
(11.81)
112 (4.4)
Ø400
(15.74)
1200 (47.24)
< 1800 (70.84)
1
2
3
12
5
10
6
6
7
7
8
9
11
7
(0.28)
40
(1.57)
4.5
(0.18)
Ø6
(0.24)
A
B
C
4
30 - 40
(1.18 - 1.57)
30 - 40
(1.18 - 1.57)
220
(8.66)
220
(8.66)
A0041199
31
Installation of seal pot PVC for CRT. Unit of measurement mm (in)
A
Float tip
B
Anchor hook details
C
Triangle bracket for measuring wire
1
Top anchor
2
Measuring wire
3
Float
4
Teflon tube
5
Guide wire (PFA-coated wire)
6
Wire protection stand (not supplied)
7
Anchor hook
8
90 ° sheave elbow
9
Seal pot
10 Measuring tape
11 Gauge supporter
12 Gauge head
• Coil the enclosed teflon tube around the measuring wire 10 to 15 times.
• Coat the anchor hook if necessary.
• Adjust contact point C in the diagram so that it is approximately 10 mm (0.39 in)
below the sheave elbow when the liquid level is 0 and approximately
100 mm (3.94 in) in relation to the gauge head when full.