![Endress+Hauser iTHERM TM401 Technical Information Download Page 5](http://html1.mh-extra.com/html/endress-hauser/itherm-tm401/itherm-tm401_technical-information_2408481005.webp)
iTHERM TM412
Hauser
5
• iTHERM TM4x2: Installed RTD thermometer with integrated HART
®
head transmitter
• Display unit RIA15:
- Display of 4 to 20 mA measured values or HART® process variables
- Loop-powered
- Voltage drop ≤1 V (HART® ≤1.9 V)
• Data Management Memograph M RSG45:
- Tamper-proof data storage and access (FDA 21 CFR 11)
- HART® gateway functionality; Up to 40 HART® devices connected at a time
- Communication capabilities: Modbus, Profibus DP, PROFINET, EtherNet/IP
• PLC / FieldCare: Field Data Manager Software MS20 - Automatic service for report generation,
printing reports, read out of data, storing of data, secure export, pdf generation Read out
measured data via online interface or from mass storage Online visualization of instantaneous
values (“live data”) . More information on this can be found in the Technical Information, see
"Documentation".
Modular design
Design
Options
7
U
5
6
1
2
3
4
A0034469
1: Terminal
head → 24
• 316L, high or low head, optionally with display window
• Aluminum, high or low head, with or without display window
• Polypropylene, low head
• Polyamide, high head, without display window
Your benefits:
• Optimum terminal access thanks to low housing edge of bottom
section:
– Easier to use
– Lower installation and maintenance costs
• Optional display: local process display unit for added reliability
• IP69K protection: optimum protection even with high-pressure
cleaning
2: Wiring,
electrical
connection,
output signal
→ 6
• Ceramic terminal block
• Flying leads
• Head transmitter (4 to 20 mA, HART
®
, PROFIBUS
®
PA,
FOUNDATION™ Fieldbus), single-channel or two-channel
• Attachable display (optional)
3: Connector or
cable gland
→ 28
• PROFIBUS
®
PA / FOUNDATION™ Fieldbus connector, 4-pin
• 8-pin connector
• Polyamide cable glands
4: Extension
neck → 28
Quick fastener iTHERM QuickNeck or NPT 1/2"
Your benefits:
•
iTHERM QuickNeck:
tool-free removal of the insert:
– Saves time/costs on frequently calibrated measuring points
– Wiring mistakes avoided
• IP69K protection: safety under extreme process conditions
5: Process
connection
→ 29
Wide range of different versions.
Summary of Contents for iTHERM TM401