IECEx BVS 12.0080 X / XA00617F-A

Gammapilot

6

Hauser

FTG20 with electronic insert FEG24 (Relay)

FTG20 with electronic insert FEG25 (8/16 mA)

Designation 
Gammapilot FTG20

Type of protection

Temperature class/surface temperature/
ambient temperature range

Operating condition

Transmitter

Sensor

.

Transmitter

Sensor

Sensor

Housing

Housing

Signal circuit

Ex d [ia] IIC T6 Gb

Ex d

Ex d

Ex ia

T6 
for Ta = –40 °C…70 °C

T6 
for Ta = –40 °C… 70 °C

Without water cooling 
or water cooling out of 
operation

Ex d [ia] IIC T4 Gb

T4 
for Ta = –40 °C…120 °C

With water cooling 
in operation

Ex tb [ia] IIIC T90°C Db

Ex tb

Ex tb

Ex ia

T90°C
for Ta = –40 °C…70 °C

T75°C 
for Ta = –40 °C… 70 °C

Without water cooling 
or water cooling out of 
operation

Ex tb [ia] IIIC T125°C Db

T125°C 
for Ta = –40 °C…120 °C

With water cooling 
in operation

Designation 
Gammapilot FTG20

Type of protection

Temperature class/surface temperature/
ambient temperature range

Operating condition

Transmitter

Sensor

.

Transmitter

Sensor

Sensor

Housing

Housing

Signal circuit

Ex d ia IIC T6...T4 Gb

Ex ia

Ex d

Ex ia

T6 
for Ta = –40 °C…40 °C

T4 
for Ta = –40 °C…70 °C

T6 
for Ta = –40 °C… 70 °C

Without water cooling 
or water cooling out of 
operation

Ex d ia IIC T4 Gb

T4 
for Ta = –40 °C…120 °C

With water cooling 
in operation

Ex tb ia IIIC T75°C Db

Ex ia

Ex tb

Ex ia

T75°C
for Ta = –40 °C…70 °C

T75°C 
for Ta = –40 °C… 70 °C

Without water cooling 
or water cooling out of 
operation

Ex tb ia IIIC T125°C Db

T125°C 
for Ta = –40 °C…120 °C

With water cooling 
in operation

Summary of Contents for Gammapilot FTG20

Page 1: ...y Instructions Gammapilot FTG20 Ex d ia IIC T Gb Ex d ia IIC T Gb Ex tb ia IIIC T Db Ex tb ia IIIC T Db IECEx BVS 12 0080 X XA00617F A Safety instructions for electrical apparatus for explosion hazard...

Page 2: ...IECEx BVS 12 0080 X XA00617F A Gammapilot 2 Endress Hauser...

Page 3: ...ction brochure CP021Z 00 Designation Explanation of the labelling and type of protection can be found in the explosion protection brochure Applied standards english Designation according to IECEx Equi...

Page 4: ...ation line Safety instructions Special conditions Connecting cable between sensor and transmitter Do not install in the vicinity of processes generating strong electrostatic charges Avoid electrostati...

Page 5: ...used only as transport protection Lay connecting cable to the transmitter and secure Transmitter housing Do not open in a potentially explosive dust atmosphere Replace cable glands and sealing plugs...

Page 6: ...T75 C for Ta 40 C 70 C Without water cooling or water cooling out of operation Ex tb ia IIIC T125 C Db T125 C for Ta 40 C 120 C With water cooling in operation Designation Gammapilot FTG20 Type of pro...

Page 7: ...253 VAC 19 55 VDC Um 253 VAC Terminal 3 4 5 and 6 7 8 relay contacts 253 VAC 4 A 1000 VA cos 1 750 VA cos 0 7 or 30 VDC 4 A 125 VDC 0 2 A FTG20_02 2 1 Terminals 2 Potential equalization Electronic in...

Page 8: ...mmapilot FTG20 with electronic insert FEG24 or FEG25 FTG20_04 4 1 Supplied cable with coded plug connectors 2 Potential equalization Sensor with connection compartment Ui 9 77 V Ii 26 7 mA Pi 78 5 mW...

Page 9: ...Gammapilot IECEx BVS 12 0080 X XA00617F A Endress Hauser 9...

Page 10: ...IECEx BVS 12 0080 X XA00617F A Gammapilot 10 Endress Hauser...

Page 11: ...Gammapilot IECEx BVS 12 0080 X XA00617F A Endress Hauser 11...

Page 12: ...www endress com worldwide XA00617F A 00 EN 01 12 71204600 CCS FM 9 0 71204600...

Reviews: