background image

Gammapilot

IECEx BVS 12.0080 X / XA00617F-A

Hauser

3

Gammapilot
FTG20

Associated 
Documentation

This document is an integral part of the following Operating Instructions:
BA01035F/00

The Operating Instructions which are supplied and correspond to the device type apply.

Supplementary 
Documentation

Explosion-protection brochure:
CP021Z/00

Designation

Explanation of the labelling and type of protection can be found in the explosion protection brochure.

Applied standards

english

Designation according to IECEx 
Equipment protection level (EPL)

Gb

Designation of explosion protection

Ex

d ia

IIC

T* Gb

Ex

d [ia] IIC

T* Gb

T* 

ä

6

Designation according to IECEx 
Equipment protection level (EPL)

Db

Designation of explosion protection

Ex

tb ia

IIIC T* Db

Ex

tb [ia] IIIC T* Db

T* 

ä

6

IEC 60079-0 :2011
IEC 60079-1 :2007
IEC 60079-11 :2012
IEC 60079-31 :2008

Summary of Contents for Gammapilot FTG20

Page 1: ...y Instructions Gammapilot FTG20 Ex d ia IIC T Gb Ex d ia IIC T Gb Ex tb ia IIIC T Db Ex tb ia IIIC T Db IECEx BVS 12 0080 X XA00617F A Safety instructions for electrical apparatus for explosion hazard...

Page 2: ...IECEx BVS 12 0080 X XA00617F A Gammapilot 2 Endress Hauser...

Page 3: ...ction brochure CP021Z 00 Designation Explanation of the labelling and type of protection can be found in the explosion protection brochure Applied standards english Designation according to IECEx Equi...

Page 4: ...ation line Safety instructions Special conditions Connecting cable between sensor and transmitter Do not install in the vicinity of processes generating strong electrostatic charges Avoid electrostati...

Page 5: ...used only as transport protection Lay connecting cable to the transmitter and secure Transmitter housing Do not open in a potentially explosive dust atmosphere Replace cable glands and sealing plugs...

Page 6: ...T75 C for Ta 40 C 70 C Without water cooling or water cooling out of operation Ex tb ia IIIC T125 C Db T125 C for Ta 40 C 120 C With water cooling in operation Designation Gammapilot FTG20 Type of pro...

Page 7: ...253 VAC 19 55 VDC Um 253 VAC Terminal 3 4 5 and 6 7 8 relay contacts 253 VAC 4 A 1000 VA cos 1 750 VA cos 0 7 or 30 VDC 4 A 125 VDC 0 2 A FTG20_02 2 1 Terminals 2 Potential equalization Electronic in...

Page 8: ...mmapilot FTG20 with electronic insert FEG24 or FEG25 FTG20_04 4 1 Supplied cable with coded plug connectors 2 Potential equalization Sensor with connection compartment Ui 9 77 V Ii 26 7 mA Pi 78 5 mW...

Page 9: ...Gammapilot IECEx BVS 12 0080 X XA00617F A Endress Hauser 9...

Page 10: ...IECEx BVS 12 0080 X XA00617F A Gammapilot 10 Endress Hauser...

Page 11: ...Gammapilot IECEx BVS 12 0080 X XA00617F A Endress Hauser 11...

Page 12: ...www endress com worldwide XA00617F A 00 EN 01 12 71204600 CCS FM 9 0 71204600...

Reviews: