Incoming acceptance and product identification
Micropilot FMR53, FMR54 FOUNDATION Fieldbus
6
Hauser
3.5.1
CE mark
The measuring system meets the legal requirements of the applicable EU directives. These are
listed in the corresponding EU Declaration of Conformity together with the standards applied.
The manufacturer confirms successful testing of the device by affixing to it the CE mark.
3.5.2
EAC conformity
The measuring system meets the legal requirements of the applicable EAC guidelines. These
are listed in the corresponding EAC Declaration of Conformity along with the standards
applied.
The manufacturer confirms successful testing of the device by affixing to it the EAC mark.
4
Incoming acceptance and product identification
4.1
Incoming acceptance
Check the following during incoming acceptance:
• Are the order codes on the delivery note and the product sticker identical?
• Are the goods undamaged?
• Does the data on the nameplate match the order specifications on the delivery note?
• Is the DVD with the operating tool present?
If required (see nameplate), have the Safety Instructions (XA) been provided?
If one of these conditions is not met, please contact your Hauser sales office.
4.2
Storage and transport
4.2.1
Storage conditions
• Permitted storage temperature: –40 to +80 °C (–40 to +176 °F)
• Use original packaging.
4.2.2
Transporting the product to the measuring point
NOTICE
Housing or antenna horn may become damaged or break off.
Risk of injury!
‣
Transport the measuring device to the measuring point in its original packaging or by the
process connection.
‣
Always secure lifting equipment (slings, eyes, etc.) to the process connection and never to
the electronic housing or antenna horn. Pay attention to the center of gravity of the device
so that it does not tilt or slip unintentionally.
‣
Follow the safety instructions and transport conditions for devices over 18 kg (39.6 lbs),
(IEC61010).