Cerabar PMC11, PMC21, PMP11, PMP21
Hauser
43
Certificates and approvals
CE mark
The device meets the legal requirements of the relevant EC directives. Hauser confirms that
the device has been successfully tested by applying the CE mark.
RoHS
The measuring system complies with the substance restrictions of the Restriction on Hazardous
Substances Directive 2011/65/EU (RoHS 2).
RCM-Tick marking
The supplied product or measuring system meets the ACMA (Australian Communications and Media
Authority) requirements for network integrity, interoperability, performance characteristics as well
as health and safety regulations. Here, especially the regulatory arrangements for electromagnetic
compatibility are met. The products are labelled with the RCM- Tick marking on the name plate.
A0029561
EAC conformity
The PMC21, PMP21 and PMP23 devices meet the legal requirements of the applicable EAC
directives. These are listed in the corresponding EAC Declaration of Conformity along with the
standards applied.
Hauser confirms successful testing of the device by affixing to it the EAC mark.
Approval
CSA C/US General Purpose
Safety Instructions (XA)
Depending on the approval, the following Safety Instructions (XA) are supplied with the device. They
are an integral part of the Operating Instructions.
Device
Directive
Documentation
Option
PMP21
ATEX II 1/2G Ex ia IIC T4 Ga/Gb
XA01271P
BA
PMC21
ATEX II 2G Ex ia IIC T4 Gb
XA01271P
BB
PMC21
PMP21
ATEX II 3G Ex ec IIC T4 Gc
XA01533P
BC
PMC21
PMP21
FM IS Cl. I, Div.1 Gr. A-D T4
XA01321P
FA
PMC21
PMP21
CSA C/US IS Cl. I Div. 1 Gr. A-D
XA01322P
CB
PMC21
PMP21
EAC Ex ia IIC T4 Ga/Gb
XA01540P
GA
PMC21
PMP21
IEC Ex ia IIC T4 Ga/Gb
XA01271P
IA
PMC21
PMP21
NEPSI Ex ia IIC T4
XA01363P
NA
PMC21
PMP21
TIIS Ex ia IIC T4
In preparation
TA
1)
Product Configurator order code for "Approval"
The nameplate indicates the Safety Instructions (XA) that are relevant to the device.