Renner 6-Light Flush Fitting

Safety Warnings

INSTRUCTION MANUAL

•  This product is only suitable for connection to a 240V~50Hz supply in accordance with current IEE wiring 

Regulations and should be installed in accordance with local Building Regulations and is for Domestic 

indoor ceiling use only and not suitable for a Bathroom location.

•  The light fitting should be connected to a lighting circuit protected by a 5 amp fuse (or a 6 amp miniature 

circuit breaker).

•  This product is a Class I fitting and 

must

 be Earthed.

•  If in doubt we recommend you contact a qualified electrician. Before installing your light fitting always 

switch off the mains supply and remove the appropriate fuse or switch off the appropriate circuit breaker 

before commencing installation, and ensure that no one else has access that would enable the supply to 

be inadvertently reconnected.

•  Never fit bulbs of a higher wattage or of a type other than those specified on the label as this may cause 

overheating and damage the fitting.

•  These product contains glass parts – be careful during handling and maintenance to avoid breakage.

•  If any modification is made it will invalidate the warranty and may render the product unsafe.

57509-Renner6lt-F  20160429

Endon Lighting, LS9 0SE

Assembly/ User Instructions

Before you start

Please read these instructions carefully before fitting and retain for reference. Check the packaging and make 

sure that you have all the required parts. Follow each assembly step in order to prevent incorrect assembly. 

Ensure that the product is fully assembled as illustrated before use.

This type of Light Fitting may be connected to a Dimmer if a Tungsten incandescent bulb is used. If a 

CFL/LED type bulb is fitted then these cannot (generally) be controlled by a dimmer.

The Light pack contains:

Light fitting.

Terminal connection block(s).

Fixing pack.

Glass plate.

Decorative drops.

The following tools may be required:

Selection of cross and flat head screwdrivers.

Electric drill and assorted drill bits.

Wire strippers.

Electrical insulation tape.

These assembly diagrams are intended as a guide – if in doubt consult a qualified electrician.

Care Information

Allow 10 minutes to cool before replacing, adjusting or cleaning.

Clean with a dry cloth only. Do not use liquid or abrasive cleaners on this product.

1.  Decide on the position of the light fitting, or remove existing light fitting. Take a note of the position of the 

electrical connections. Ensure there is a solid mounting surface, preferably a wooden joist or joist bridge to 

support the weight of the light fitting. 

2.  Remove the fixing bracket by undoing the 2 side screws (3), retain for re-use.

3.  Use the fixing bracket as a template to mark the screw holes, mark the screw holes and secure to the ceiling 

with the fixings (1) supplied.

4.  Slide the glass plate (4) over the body of the fitting so it rests on the lip, and secure in place with the metal 

tab and screw (5)