Response (Required) The following table illustrates the response to the received command and the error
responses;
Command #
Command
13x Response
0x00
Setup to 13x
ACK
0x01
Cal Constants to 13x
ACK
0x02
Setup from 13x
Cmd <data>
0x03
Cal Constants from 13x
Cmd <data>
0x04
Calibrated Vout data
ACK ....Cmd <data>
0x05
Raw Vout data
ACK ....Cmd <data>
0x06
Stop Data
ACK
0x07
Data Interval to 13x
ACK
0x08
Reset Unit
ACK
0x09
Unit ID from 13x
Cmd <data>
0x0A
LP Corners from 13x
Cmd <data>
0x0B
Error List from 13x
Cmd <data>
0x0C
ACK
Reason
13x Error Responses
0x0D
Bad CS or Not enough data
NAK
0x0E
Channel # too high
Bad Channel
0x0F
Setup value out of range
Bad Setup
0x10
Hw setup unit reports error
Setup Error
0x11
Setup value out of range
Bad Cal Constant
Response Data (conditional): The following sections describe the response of the 13x to commands that
require it to send data (all data described below follows a transmission Header identical to that described
above).
Channel Setup Data - The data sent in response to the ‘Setup from 13x’ command (0x02) is identical to
the format of the Setup to 13x’ command (0x00) described above. If the channel number indicated in the
header equals zero (0) then data will be sent for all three channels.
Calibration Constant Data - The data sent in response to the ‘Cal Constants from 13x’ command (0x03)
is identical to the format of the Cal Constants to 13x’ command (0x01) described above. If the channel
number indicated in the header equals zero (0) then data will be sent for all three channels.
Calibrated Vout Data - The data sent in response to the ‘Calibrated Vout Data ‘command (0x04) will be
for the channel indicated in the transmission header. If the channel number equals zero (0) then data will
be sent for all three channels. The transmission of data for the indicated channel(s) will continue at the
rate specified by the ‘Data Interval to 13x’ command. The data will be one or three values formatted to be
a decimal integer string. To render it back to a floating point number it should first be converted from a
string to an integer and then divided by 1000.
NOTE: If the unit is not in the ‘Normal’ mode of operation at the time it is scheduled to output
data remotely, that data transmission will be skipped.
Raw Vout Data - The format of the data sent in response to the ‘Raw Vout Data ‘ command (0x05) is
identical to the Calibrated Vout Data discussed above.
Unit ID Data - The data sent in response to the ‘Unit ID from 13x ‘ command (0x09) is a string which
states the Model number and the firmware revision (i.e 133 REV A).