Only use the MANUAL ACTIVATION / RESET button when a problem has been detected, and

     after you have resolved the issue causing the problem.

■  

Pressing the MANUAL ACTIVATION / RESET button will cause the REVERSE POLARITY

     protection to be DISABLED until such time as the SMART CABLE is physically disconnected / 

     reconnected to the jump start unit.

■  

In such situation, be very careful NOT to reverse the polarity when this button has been pressed.  

    Otherwise you may cause damage to the cable and the jump start unit.

MOBILE PHONE / TABLET / PC CHARGING

A series of charging adaptors are supplied with this unit.  However, we recommend using the charging 

cable supplied with your original product.  For phones / tablets, plug the USB port of the charging cable 

into the USB 5V output port, and the adaptor to your device.  
The 12V DC connection can be used for charging 12V devices. The maximum output current is 15A.

RECHARGING THIS UNIT

Press the POWER switch to start charging. This unit should be charged using the a 240V AC (15V / 1A) 

adaptor supplied. 
Using the 240V AC adaptor, it will take approximately 5 hours to fully charge the unit.  

To extend the battery life, it is recommended to fully charge the unit every 3 - 6 months.

LED LIGHTS

Further pressing the power switch will cycle between SOS mode, flashing mode, and then off.  Depress the 

POWER switch for 3 seconds to directly turn off the LED light.

SPECIFICATIONS

Capacity                                                     16,800mAh
Peak current                                             1200CCA
Charging                                                    DC15V/1A (5 hrs)
USB output                                                U USB5V2.1A
DC output                                                 12V - 16V/15A          
Working temperature                            -20

o

C to 60

o

C

Storage temperature                             -20

o

C to 60

o

C

Summary of Contents for ET6795

Page 1: ... Manual Read all safety warnings and instructions Failure to follow warnings and instructions may result in electric shock fire and or serious injury FOR 12V AUTOMOTIVE BATTERIES ONLY READ THIS MANUAL CAREFULLY BEFORE USE SAVE THESE INSTRUCTIONS VER 1015 30AA ...

Page 2: ...ng the jump start function do not allow the positive and negative poles to contact each other This may cause sparking and result in a safety hazard and cause a short circuit of the unit When using the jump start function use for 3 seconds only Allow 1 minute for unit to cool before attempting a further jump start Disconnect the cable from the unit immediately upon engine starting BATTERY This unit...

Page 3: ...RVIEW 1 ON OFF button 2 USB output 3 DC15V input 4 1W LED light 5 DC12 16V output 6 Battery indicator 7 EC5 output Dust cover 1 2 3 4 5 6 7 Indicator light Negative black Manual Activation Reset Button Positive red ...

Page 4: ...unit to cool down As additional protection the SMART START cable will also automatically cut the output after a five 5 jump start actions or b after one minute Please refer to the MANUAL ACTIVATION RESET button section below Use this unit with 12V automotive batteries ONLY with a CCA rating of 1200CCA or less You must NOT attempt to jump start vehicles with a higher battery rating or different vol...

Page 5: ...hat the connection is correct and you may now attempt to turn your ignition key to start the engine Do this within 1 minute Otherwise the SMART START cable will automatically disconnect and will need to be reset E If the SMART START cable detects a problem the indicator light will turn RED Please correct the problem and press the RESET button to start again The problems may be due to a short circu...

Page 6: ...ection by pressing the MANUAL ACTIVATION RESET button Refer from D above A short circuit or reverse polarity situation is detected Solution Resolve the problem first then press the MANUAL ACTIVATION RESET button to reset the cable The green indicator light will start flashing Refer from D above Only use the MANUAL ACTIVATION RESET button when a problem has been detected and after you have resolved...

Page 7: ...start charging This unit should be charged using the a 240V AC 15V 1A adaptor supplied Using the 240V AC adaptor it will take approximately 5 hours to fully charge the unit To extend the battery life it is recommended to fully charge the unit every 3 6 months LED LIGHTS Further pressing the power switch will cycle between SOS mode flashing mode and then off Depress the POWER switch for 3 seconds t...

Page 8: ... C Endeavour Tools may replace or repair the defective good or part thereof or refund the purchase price of the defective good at its option D Endeavour Tools shall not be responsible for any loss or damage arising from or in any way connected with the use of the goods E To the maximum extent permitted by law a claim in respect to a defective good shall not be permitted in the event that the goods...

Reviews: