background image

Revision Date

20130723

Document numbeR

notice 

The manufacturer will accept no responsability for any electrical 

damage resulting from improper installation of this product, be that either 

damage to the vehicle itself or to the installed device. This device must be in-

stalled by a certified technician. Please review the Installation Guide carefully 

before beginning any work. 

beFoRe instaLLation

1- Connect module to computer

2- Login to Weblink account

3- Flash firmware to module (module is not preloaded with firmware)

4- Use accessories accordingly (accessories are sold separately)

instaLL guiDe

COM-IDS(RS)-BM1-EN

haRDwaRe

ADS-BM1

FiRmwaRe

COM-IDS(RS)-BM1

compustar.idatalink.com

Automotive Data Solutions Inc. © 2013

accessoRies

PROGRAMMING CABLE ADS-USB (REQUIRED)

COMPATIBLE RF-KIT (OPTIONAL)

DRONE MOBILE DR-2000 (OPTIONAL)

FT-D100 (OPTIONAL)

11866

Summary of Contents for COM-IDS(RS)-BM1-EN

Page 1: ...Installation Guide carefully before beginning any work BEFORE INSTALLATION 1 Connect module to computer 2 Login to Weblink account 3 Flash firmware to module module is not preloaded with firmware 4 U...

Page 2: ...AKE PEDAL STATUS MONITORING VSS STATUS MONITORING GLOW PLUG STATUS MONITORING DOOR STATUS MONITORING TRUNK STATUS MONITORING HOOD STATUS MONITORING BMW 1 Series PTS AT 08 13 1 3 Series PTS AT 06 11 1...

Page 3: ...HARNESS 1 T HARNESS 2 T HARNESS 2 EXPANSION CABLE AFTERMARKET HOOD SWITCH AND CABLE STICKER 1 10 PIN WHITE CONNECTOR 12 PIN BLACK CONNECTOR EXPANSION PACK MODULE ACCESSORIES SOLD SEPARATELY BOX CONTEN...

Page 4: ...icle Disassembly Procedure videos Module Connection Procedures videos Module Programming Procedures videos Simply visit our forum and register at http www 12voltdata com forum viewtopic php f 340 t 96...

Page 5: ...will result in vehicle displaying error messages An OEM scantool will be required to clear the error messages START vehicle Verify all vehicle functionalities WARNING If the vehicle displays error mes...

Page 6: ...STEP 4 CONNECT THE FOLLOWING IF REQUIRED 07 GRAY WHITE HOOD STATUS INPUT BLACK 4 PIN RF CABLE BLUE 4 PIN TELEMATIC CABLE AFTERMARKET HOOD SWITCH 08 GRAY BLACK NC RF KIT TELEMATIC IF NOT EQUIPPED WITH...

Page 7: ...om keyport WARNING Follow steps 4 3 2 as shown in the wiring diagram to disconnect the module from the vehicle Connect module to computer and proceed with KLON programming WARNING Follow steps 2 3 4 a...

Page 8: ...Open hood Question 4 Is the orange warning sticker Sticker 1 placed under the hood YES Leave hood open and go to step 9 NO Put the mandatory orange warning sticker Sticker 1 leave hood open and go to...

Page 9: ...the OEM keyfob Within 45 seconds go to step 22 22 Open driver door Question 9 Does the vehicle shut down YES For Z4 X5 X6 Go to step 25 YES For 1 3 5 6 X1 The module does NOT detect the parking brake...

Page 10: ...estriction Complete next step within 7 seconds Cycle ignition ON five times 5x OFF ON rapidly Parking Light will ash once 1x Wait Parking Light will ash twice 2x pause for 1 5 second then will ash onc...

Page 11: ...on ON five times 5x OFF ON rapidly Parking Light will ash once 1x Time restriction Complete next step within 5 seconds from previous step Press once 1x on LOCK button of aftermarket remote Parking Lig...

Page 12: ...ill ash RED an equal amount of times continuously TO ACCESS THE SETTINGS Press and hold programming button until LED 1 turns solid GREEN LED 1 will ash GREEN as many times as the current or default se...

Page 13: ...5 TAKEOVER 01 enabLe 02 DISABLE 06 SECURE TAKEOVER DELAY 01 45 sec 02 90 SEC 03 03 MIN 04 04 MIN 07 FACTORY KEYLESS RS SEQUENCE 01 DISABLE 02 N A 03 LOCK UNLOCK LOCK 04 LocK LocK LocK 08 MODULE RUN TI...

Page 14: ...coDes notes Y numbeR oF PaRKing Light FLashes Diagnostic I WARNING The following applies only when the parking lights are connected and supported by the system 01 Engine tach signal is lost 02 N A II...

Page 15: ...grammed Solid RED Module incorrectly programmed Flashing GREEN Module correctly programmed and operational Solid GREEN then OFF Reset in progress OFF Invalid ground when running status from remote sta...

Page 16: ...while connecting the BLACK 20 PIN connector Wait LED 1 will ash RED RELEASE programming button LED 1 will turn RED for 2 seconds Module RESET completed Reconnect all connectors Repeat programming proc...