SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.
Yukarı Dudullu Barbaros Cd. No:
18
34775 - ÜMRANİYE/İSTANBUL-TÜRKİYE
Tel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01
url : www.enda.com.tr
4/
4
ET
2011
-
E
-0
4-R
3
5
m
m
77mm
5
6
SUPPLY:
NOTE :
184-253V AC
50/60Hz 5VA
Phase
Neutral
230V AC
Supply
Switch
Cable size: 1,5mm²
Fuse
F 100 mA
250V AC
Fuse should
be connected.
Order Code
:
ET
2011-X
-
XXX- X
Supply voltage
230
VAC
...
...
230V AC
110VAC......110V AC
0
24
VAC
........24V AC
SM.......9-30VDC/7-24V AC
Contact current selection
None......8A contact output
P
....
16A contact output
Input selection
RT....PT100 input
T
....
TC input
SET
°C
SET
ET2011
ENDA
°F
C/A2
SSR
F
Flush
mounting
clamp
2
8
m
m
Panel cut-out
1
Flush mounting
clamp
Panel
2
73mm 5mm
Depth
Connection
cable
CONNECTION DIAGRAM
DIMENSIONS
Note
1) Panel thickness should be maximum 7mm.
2) If there is no 60mm free space at back side of the device,
it would be difficult to remove it from the panel.
To remove the device from panel:
ENDA ET2011 is intended for installation in control panels. Make sure that the device is used only for intended
purpose. The shielding must be grounded on the instrument side. During an installation, all of the cables that are
connected to the device must be free of energy. The device must be protected against inadmissible humidity,
vibrations, severe soiling and make sure that the operation temperature is not exceeded. All input and output lines
that are not connected to the supply network must be laid out as shielded and twisted cables. These cables should
not be close to the power cables or components. The installation and electrical connections must be carried on by
a qualified staff and must be according to the relevant locally applicable regulations.
1) Mains supply cords shall meet the requirements
of IEC 60227 or IEC 60245.
2) In accordance with the safety regulations, the
power supply switch shall bring the identification of
the relevant instrument and it should be easily
accessible by the operator.
Note
Holding screw
0.4-0.5Nm
Equipment is protected throughout
by DOUBLE INSULATION.
-While pushing the clamp in direction 1,
pull out it in direction 2.
71mm
8 680407 711246
8 680407 711284
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
ENDA
INDUSTRIAL ELECTRONICS
ENDA
INDUSTRIAL ELECTRONICS
SN: XXXXXXXXX
SN: XXXXXXXXX
ET20
1
1-T-230
PID DIGITAL THERMOSTAT
ET20
1
1-T-230-P
PID DIGITAL THERMOSTAT
230V AC +10% -20%
50/60Hz 5VA
230V AC +10% -20%
50/60Hz 5VA
11
11
12
12
C/A2
250V AC 8A
RESISTIVE LOAD
C/A2
250V AC 16A
RESISTIVE LOAD
TC
TC
+
+
-
-
-
-
+
+
S
S
R
O
U
T
S
S
R
O
U
T
MADE IN TURKEY
MADE IN TURKEY
8 680407 711321
1
2
3
4
5
6
7
8
9
10
ENDA
INDUSTRIAL ELECTRONICS
SN: XXXXXXXXX
ET20
1
1-RT-230
PID DIGITAL THERMOSTAT
230V AC +10% -20%
50/60Hz 5VA
11 12
C/A2
250V AC 8A
RESISTIVE LOAD
-
+
S
S
R
O
U
T
PT100
MADE IN TURKEY
8 680407 711369
PT100
1
2
3
4
5
6
7
8
9
10
ENDA
INDUSTRIAL ELECTRONICS
SN: XXXXXXXXX
ET20
1
1-RT-230-P
PID DIGITAL THERMOSTAT
230V AC +10% -20%
50/60Hz 5VA
11 12
C/A2
250V AC 16A
RESISTIVE LOAD
-
+
S
S
R
O
U
T
MADE IN TURKEY
8
6
8
0
4
0
7
7
1
1
2
4
6
1
2
3
4
5
6
7
8
9
10
EN
DA
IN
DU
ST
RIA
L E
LE
CT
RO
NIC
S
SN
: X
XX
XX
XX
XX
ET
20
1
1-T
-2
30
PID
D
IG
IT
AL
T
HE
RM
OS
TA
T
23
0V
A
C +
10
% -
20
%
50
/6
0H
z
5V
A
11
12
C/A
2
25
0V
A
C 8
A
RE
SIS
TIV
E L
OA
D
TC
+
-
-
+
S
S
R
O
U
T
MA
DE
IN
T
UR
KE
Y
8
6
8
0
4
0
7
7
1
1
2
4
6
1
2
3
4
5
6
7
8
10
EN
DA
IN
DU
ST
RIA
L E
LE
CT
RO
NIC
S
SN
: X
XX
XX
XX
XX
ET
20
1
1-T
-2
30
PID
D
IG
IT
AL
T
HE
RM
OS
TA
T
23
0V
A
C +
10
% -
20
%
50
/6
0H
z
5V
A
11
12
C/A
2
25
0V
A
C 8
A
RE
SIS
TIV
E L
OA
D
TC
+
-
-
+
S
S
R
O
U
T
MA
DE
IN
T
UR
KE
Y