background image

Never stand directly below the device when mounting, removing, or ser vicing the 

fixture.

from a ceiling, or set on a flat level surface (see illustration below). Be sure this fixture 

is kept at least 0.5m (1.5 ft) away from any flammable materials (decoration etc.).

Always use and install the supplied safety cable as a safety measure to prevent 

accidental damage and/or injur y in the event the clamp fails.

Mounting points: 

Overhead mounting requires extensive experience, including 

amongst others calculating working load limits, a fine knowledge of the installation 

material being used, and periodic safety inspection of all installation material and the 

fixture. If you lack these qualifications, do not attempt the installation yourself. 

Improper installation can result in bodily injur y.

Be sure to complete all rigging and installation procedures before connecting the 

main power cord to the appropriate wall outlet.

Clamp Mounting: 

 provides a unique mounting bracket 

assembly that integrates the bottom of the base, and the safety cable rigging point in 

one unit (see the illustration below). When mounting this fixture to truss be sure to 

secure an appropriately rated clamp to the included omega bracket using a M10 

screw fitted through the center hole of the “omega bracket”. As an added safety 

measure be sure to attached at least one properly rated safety cable to the fixture 

using on of the safety cable rigging point integrated in the base assembly.

AuraWash ™ 19QUAD EFX

.06.

① 

Omega

 

Bracket

② 

Satety

 

Clamp

③ 

Safety

 

Cable

④ 

1

/

4

 

Turn

 

Quick

-

Lock

 

Fasteners

1/4 Turn 

1/4 Turn 

DMX CHANNELS

9

.09.

Function 

Values 

Description

21CH 35CH

92CH

0-100% Linear red dimmer

Fine control of red

0-100% Linear green dimmer

Fine control of green

0-100% Linear blue dimmer

Fine control of blue

0-100% Linear white dimmer

Fine control of white

NO Function

Linear color temperature from 2500K-8000K

Macro color OFF

Red

Green

Blue

Cyan

Yellow

Magenta

White 7000 K

White 3700 K

White 5000 K

Black

Medium Yellow

Straw Tint

Surprise Peach

Fire

Medium Amber

Gold Amber

Dark Amber

Sunrise Red

Light Pink

Medium Pink

Pink Carnation

Light Lavender

Lavender

Sky Blue

Just Blue

Dark yellow green

Spring Yellow

Light Amber

Straw

Deep Amber

0-255

0-255

0-255

0-255

0-255

0-255

0-255

0-255

0-10

0-255

0-09

10

11

12

13

14

15

16

17

18

19

020-022

023-026

027-028

29

30

31

032-034

035-044

45

046-048

049-061

062-067

068-077

078-088

089-099

100-109

110-111

112

113

114

Red

Red Fine

Green

Green Fine

Blue

Blue Fine

White

White Fine

Linear CTO

Macro Color

1

2

3

4

5

6

7

8

9

10

1

2

3

4

5

6

7

8

9

10

1

2

3

4

5

6

7

8

9

10

78CH

1

2

3

4

5

6

7

8

9

10

97CH

1

2

3

4

5

6

7

8

9

10

Summary of Contents for AuraWash 19QUAD EFX

Page 1: ...User Manual KEEP THIS MANUAL FOR FUTURE NEEDS tc 150 C LED 0 2m ta 40 C AuraWash 19QUAD EFX ...

Page 2: ... instructions and warning notes written in this user manual CAUTION Becareful with your operations With a dangerous voltage you cansuffer a dangerous electric shock when touching wires IMPORTANT Damages caused by the disregard of this user manual are not subject to warranty The dealer will not accept liability for any resulting defects or problems SAFETY INSTRUCTIONS 1 The following points have to...

Page 3: ... damaged during the transportation And please check whether the following items are included inside the box AuraWash 19QUAD EFX AuraWash 19QUAD EFX AuraWash 19QUAD EFX 02 UNPACKING 2 AuraWash Signal Cable Power Cable Omega Clamp Safety Cable User Manual 1PC 1PC 1PC 1PC 1PC 1PC Euro Standard UK Standard USAStandard OPTIONAL 03 Slow pulsation 0 5 flash sec Fast pilsation 25 flash sec Open Random slo...

Page 4: ...e with die cast plastic cover Two side handles for transportation PAN lock for transport and maintenance High efficiency low noise cooling system Constant temperature readout and management function 45 C max ambient temperature IP20 protection rating 55dB at 3 dB rating 2 1 4 turn fastening Omega clamp 1 Safety attachment point Art Net King Net DMX 12 Two rotating arcs of different colors Two rota...

Page 5: ...sble density and speed 0 230 TILT movement Fine control of TILT No Function Zoom reset Pan Tilt reset Complete reset 0 100 Linear zoom Linear roation Slow rotation Stop Slow rotation Macro OFF Ring 1 Ring 2 Ring 3 No function Ring 1 2 Ring opening closing Rainbow 1 Varisble speed Rainbow 2 fixed speed with variable color offset Fan 3 ams Bar 2 ams Half moon Triangle Two rotating bars of different ...

Page 6: ...there are any malfunctions from not following the user manual to operate or any illegal operation like shock short circuit electronic shock lamp broke etc AuraWash 19QUAD EFX 05 OPERATION INSTRUCTIONS 5 Cautions For added protection mount the fixtures in areas outside walking paths seating areas or in areas were the fixture might be reached by unauthorized personnel Before mounting the fixture to ...

Page 7: ... screw fitted through the center hole of the omega bracket As an added safety measure be sure to attached at least one properly rated safety cable to the fixture using on of the safety cable rigging point integrated in the base assembly AuraWash 19QUAD EFX 06 Omega Bracket Satety Clamp Safety Cable 1 4 Turn Quick Lock Fasteners 1 4 Turn 1 4 Turn DMX CHANNELS 9 09 Function Values Description 21CH 3...

Page 8: ... it is recommended to use a DMX terminator This helps in preventing corruption of the digital control signal by electrical noise The DMX terminator is simply an XLR plug with a 120 Ω resistor connected between pins 2 and 3 which is then plugged into the output XLR socket of the last fixture in the chain Please see illustrations below 1 2 3 PIN3 PIN2 120 Ω MENU OPERATIONS 8 Address Test Intro Users...

Reviews: