BANDIT III Hardware Description

Page 13

Go to 

Table of 

Contents

Go to 

Top 

Doc

Go to 

List of 

All Docs

LAN 10/100 
(Three ports: 
LAN1, LAN2, 
and LAN3)

LAN1: Tenth, 
LAN2: 
Thirteenth, 
LAN3: 
Sixteenth

Green 100Base-T

Off 10Base-T

LAN Carrier 
Detect/
Activity 

LAN1: 
Eleventh, 
LAN2: 
Fourteenth, 
LAN3: 
Seventeenth

Green

Connection to LAN has been made. 

Off

Connection to LAN has failed.

Green flashing

Data is being transmitted or received. 

LAN Half 
Duplex/Full 
Duplex

LAN1: Twelfth, 
LAN2: 
Fifteenth, 
LAN3: 
Eighteenth

Green Full 

Duplex

Off

Half Duplex 

Cellular
Carrier 
Detect/
Activity

Nineteenth 

Green 

Connection has been made to a cellular 
wireless carrier. 

(Flashing)

The LED flashes one to five times to 
show signal strength. The number of 
flashes in a set is equivalent to the same 
number of bars displaying signal 
strength on a mobile phone. 
Flashes display in one of the following 
patterns: 
• A set of short flashes followed by a 

longer final flash indicates that 
connection to a cell tower has been 
authenticated. Sample flash pattern: 

• A set of short flashes followed by a 

pause indicates that there is a signal 
from a cell tower but that the 
connection has not been 
authenticated. The device may need 
to be activated. Sample flash pattern: 

The number of short flashes in a set 
indicates the signal strength. A long 
flash is not counted as part of the signal 
strength. 

Off 

Not activated. The device has not been 
authenticated for a wireless carrier and 
is not receiving a signal. 

Table 1-6. BANDIT III General Status LED Definitions

 (Sheet 2 of 3)

LED 

Location 
(from left 
side)

1

 

Color 

Description 

_

`

_ _

_

_

`

_ _

_

_ _ _

_

_

`

_ _

_

_

`

_ _

_

_ _ _

_

Top Doc

Doc List

Module TOC

Summary of Contents for BANDIT III

Page 1: ...ally hardened chassis with a metal cover Hardened construction allows the BANDIT III to operate over wide temperature ranges at remote sites that do not use environmental control The BANDIT III like a...

Page 2: ...T III Chassis with Ethernet Switch Module Expanded BANDIT III Chassis with Internal Data Unit BANDIT III E M Signaling Chassis 1 1 1 Standard BANDIT III Chassis The basic BANDIT III chassis Figure 1 2...

Page 3: ...24 48 volts DC input power Figure 1 5 or for 12 24 volts DC input power Figure 1 6 When you order a BANDIT III you specify the type of input power it will use Note Each DC powered BANDIT III chassis a...

Page 4: ...nd 110 220 VAC Input Power Figure 1 6 BANDIT III Chassis Rear Panel Basic Model 12 24 VDC Input Power or Failover 12 24 VDC and 110 220 VAC Input Power The following items are on the back of the basic...

Page 5: ...or X 21 56k CSU DSU port T1 E1 CSU DSU port Dual port T1 E1 CSU DSU port with drop and insert capability A second wireless card this can be the same type CDMA EVDO CDMA GPRS GSM or EDGE GSM as the in...

Page 6: ...a Unit As stated earlier the BANDIT III is also available in an expanded model with an Internal Data Unit IDU comprising four DB25 serial ports for additional VPN functionality The expanded BANDIT III...

Page 7: ...igurations for the BANDIT III chassis Two failover input power configurations 24 48 VDC with 110 220 VAC or 12 24 VDC with 110 220 VAC Each BANDIT III chassis that uses DC input power basic Figure 1 4...

Page 8: ...III is available in models that accept power from a DC power source at 24 48 VDC or 12 24 VDC or in models that accept power from an industry standard autosensing 100 240 VAC adapter connected to an A...

Page 9: ...connections to network devices Section 1 1 9 1 Ethernet Ports Section 1 1 9 2 Modem Port Section 1 1 9 3 Serial Port Section 1 1 9 4 Wireless Ports Also see Section 1 1 10 Expansion Ports Note The BA...

Page 10: ...tp SNMP MIB II ARP Proxy ARP Routing over VPN tunnels 1 1 9 2 Modem Port An internal modem resides in the BANDIT III Connect the modem port to an RJ11 telephone jack 1 1 9 3 Serial Port The BANDIT III...

Page 11: ...ion ports available in the BANDIT III see Ports in the BANDIT Products If the expansion port is for a wireless connection also see Wireless Cards for BANDIT Products 1 2 Status LEDs Light emitting dio...

Page 12: ...4 indicates that the connection is up between that serial port and its connected device Table 1 6 describes the BANDIT III s LEDs Table 1 6 BANDIT III General Status LED Definitions Sheet 1 of 3 LED...

Page 13: ...in a set is equivalent to the same number of bars displaying signal strength on a mobile phone Flashes display in one of the following patterns A set of short flashes followed by a longer final flash...

Page 14: ...ow fifth from left Green Connection has been made to carrier Off Connection to carrier has failed Link for IDU Port 45 Top row sixth from left Green Connection has been made to carrier Off Connection...

Page 15: ...G Good frames are passing through Byte Sync Encapsulation Good frames are passing through X 25 Level II connection exists Telnet Terminal Data transfer in either direction 1 When using spoofed protoco...

Page 16: ...Page 16 BANDIT III Reference Module Document 1 Go to Table of Contents Go to Top Doc Go to List of All Docs Top Doc Doc List Module TOC...

Reviews: