Attention!
The total pressure inside the line must never exceed 0.5 bar. If a backpressure or
underpressure inside the line builds up, the device will go into error mode and get
permanently damaged.
Enapter is not responsible for any damage caused to the device from mismanaged piping
arrangements.
To connect
the port labelled “O
2
Vent”
, use heat and KOH resistant pipes, sealings and connectors only.
If connecting several devices to a common vent line, make sure the diameter of the line is sufficient
and that it always runs declining. As water is condensing inside the vent lines, there must not be any
horizontal or sagging sections. The condensing water would block the pipe.
At the lowest point of the vent line, a drain trap or similar device must be installed to separate the
condensed water from the oxygen (see picture).
The oxygen vent outlet must lead to a safe area. The water from the water trap must be drained
according to local laws and regulations as it may contain traces of KOH.
Warning!
The gaseous outputs from the oxygen vent and the hydrogen vent must be kept
separated. Mixing of these outputs results in an explosive atmosphere.
O
2
VENT line and water trap