SETTINGS IN THE PROFESSIONAL MODE
smart Stove - 0142 - 42WMSUGAT2-C
69
Max. temp DHW *
60
20 ... 90
°C
Maximum tempera-
ture for external
domestic hot water
tank
x
x
Charge diff DHW *
3
1 ... 5
K
Control of the pump
for domestic hot water
with conditions:
TS2 > TS5 +
Charge diff DHW
and
TS5 < Max. temp DHW –
Charge hys DHW
x
x
Charge hys DHW *
6
2 ... 10
K
x
x
DRD DHW Eco
100
0 ... 500
min*K
Dynamic recharge
delay for domestic hot
water heating - econ-
omy mode
x x
x x x
DRD DHW Comf
0
0 ... 500
min*K
Dynamic recharge
delay for domestic hot
water heating heating
- comfort mode
x x
x x x
Anti-legionellae *
x x x x x x x
Activation *
Yes
No/Yes
Activation of anti-legi-
onella function
x x x x x x x
Target temp *
60
55 ... 85
°C
Target temperature for
disinfection
x x x x x x x
Hysteresis *
3
1 ... 5
K
Temperature hystere-
sis for switch-on
x x x x x x x
Start time *
3
0 ... 23
hour
Starting time for heat-
ing
x x x x x x x
Duration *
10
5 ... 60
min
Duration of the
required heating cycle
x x x x x x x
Max. time *
48
4 ... 96
h
Maximum heating
period (timeout)
x x x x x x x
Use add. heat *
Yes
No/Yes
Use additional heating
for disinfection
x x x x x x x
Menu/parameter
Default Range
Unit
Description
Hydraulic system
Basic functions
1 2 3 4 5 6 7