SETTINGS IN THE PROFESSIONAL MODE
68
smart Stove - 0142 - 42WMSUGAT2-C
Common Eco/Comf *
Yes
No/Yes
Disable or enable the
›Operation mode‹ dis-
play (during commis-
sioning only)
x x x x x x x
fix PWM *
30
5 ... 100
%
Fixed PWM speed of
high efficiency pump
for loading domestic
hot water/external AH
x
x x
Min control PWM *
30
5 ... 100
%
Lower PWM speed
level for controlling
the stove charging
pump
x x x
Step PWM *
5
2 ... 10
%/K
PWM pump speed
increment
x x x
Domestic hot water
x x x x x x x
Req. add. heat
50
20 ... 90
°C
Setpoint for request
for heat from stove
with additional heat-
ing. If the tank temper-
ature falls below this
temperature the
request will be acti-
vated.
x x
x x x
Offset add. heat *
+5
1 ... +20
K
Offset for deactivat-
ing request for heat
from stove with addi-
tional heating
x x
x x x
Req. stove
55
20 ... 90
°C
Setpoint for request
for heat from stove. If
the tank temperature
falls below this tem-
perature the request
will be activated.
x x x x x x x
Offset stove *
+10
1 ... +50
K
Offset for deactivat-
ing request for heat
from stove
x x x x x x x
Menu/parameter
Default Range
Unit
Description
Hydraulic system
Basic functions
1 2 3 4 5 6 7