102
Professional mode
Soft charging sets the plant to
protection mode to prevent
excessively high tank temperatures.
The start temperatures for two
tank circuits and the appropriate
calendar period are determined here.
Return to ›Main menu‹.
Continue with ›Monitoring‹.
Here, the parameters
for tank cooling are defined.
›t-ON‹ and ›t-OFF‹ are used to define
the appropriate time slot in which the
tank is to be cooled via the collector,
and ›Hyst.tank 1‹ and ›Hyst.tank
2‹ are used to define the switch-ON
hysteresis.
If the adjusting balance is activated,
the heat dissipated via the collector
is deducted from the energy balance
calculation.
Continue with ›Soft charge‹.
Note!
To protect the pump, the collector emergency switch-off in
solar circuits with high-efficiency pumps is reduced to 100°C.
Soft charge is not possible at higher temperatures!
Activation
Hyst.tank 1
Hyst.tank 2
t ON
t OFF
Adjusting balance
2.0K
2.0K
00:00
07:00
1.5.5 Cooling funct.
25.08.2012
10:43
Activation
T min. tank 1
T min. tank 2
Start
End
45.0°C
45.0°C
30.05.
31.07.
1.5.6 Soft charge
25.08.2012
10:43