The  MVP D-TEK  vehicle  loop  detector  allows  for  detection of  metallic  objects entering  the  field  formed 
around an induction loop. This detector automatically adjusts to input power from 12 VDC up to 240 VAC 

which eliminates the installer’s need to match available power to an appropriately rated vehicle detector. 

The MVP D-TEK is made from anodized aluminum and all switches have gold plated contacts that are sealed 
for protection. It features full loop diagnostic with frequency counter, 10 sensitivity settings, delay mode, 
extend mode, fail safe/fail secure mode, automatic sensitivity boost, pulse and presence operating modes 
and two output relays. 

 

Cautions and Warnings

 

 

This  product  is  an  accessory  or  part  of  a  system.  Install  the  MVP  D-TEK  according  to 
instructions  from  the  gate  or  door  operator  manufacturer.    Comply  with  all  applicable  
codes and safety regulations.  

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

MVP D-TEK   

Multi-voltage vehicle loop detector (included) 

 

HAR-11   

 

11 position harness, 3

’ 

of wire 

 

LD-11 

 

 

11 pin DIN rail socket, black, wide base 

 

LD-11B   

 

11 pin DIN rail socket, black, narrow base 

 

PR-XX 

 

 

Lite preformed loop (XX 

 specify size) 

 

TSTL 

 

 

Test loop, troubleshooting tool 

Specifications

 

Power 

12-60 VDC or 12-240 VAC (48-62 Hz) 

Draw Current 

19.2 mA 

Loop Frequency 

3 settings (low, medium, high) 

Loop Induction 

20-

2000 μH (Q factor ≥ 5)

 

Surge Protection 

MOV, neon and silicon protection devices 

Relay Contact Rating 

2 DPST 1A @ 30 VDC 

Operating Temperature 

-40º to 180ºF (-40º to 82ºC) 

Housing Material 

Anodized aluminum 

Connector 

11 pin male connector (JEDEC B11-88) 
compatible with DIN rail mount socket or wire harness 

Dimensions (L x W x H) 

3.25” (83 mm) x 2.56” (40 mm) x 3.65” 

(90 mm) 

Ordering Information

 

TM 

Summary of Contents for MVP D-TEK

Page 1: ...relays Cautions and Warnings This product is an accessory or part of a system Install the MVP D TEK according to instructions from the gate or door operator manufacturer Comply with all applicable cod...

Page 2: ...0 VDC AC 2 Black Power 12 240 VDC AC 3 Orange Relay 2 NO normally open contact 4 Green Earth Ground 5 Yellow Presence 1 COM common contact 6 Blue Presence 1 NO normally open contact 7 Gray Loop 8 Brow...

Page 3: ...presence output in the event of a loop failure and the detector will not change states on power loss or power up In Fail Secure mode relay 2 will trigger if a loop fault occurs Do not use Fail Secure...

Page 4: ...es the detector to the local inductance field DIP switch settings and frequency setting Momentarily flipping the switch up to check the operating frequency will cause the red LED to flash Each flash r...