CellOpener-365_Rev1.0_0601201 [email protected]
Relay’s function is set for Latch function
If the unit is set for PULSE then:
The relay function is set to Pulse for 1 second
If the unit is set for LATCH then:
The relay is set to Latch Function
6.
How to Set the Relay’s Pulse Time
The factory default time setting for the relay is a Pulse of 1 second. You can choose and set the
PULSE time interval of the relays by SMS as follows:
9999pulse_ _
The two underscores “ _ _ ” after the word “pulse” represent the time in seconds up to 99
seconds. Use the following commands to set the pulse time:
*9999 Is the password (default password 9999)
9999pulse00
for
½
a second pulse time.
9999pulse01
for 1 second pulse time (Factory Default)
9999pulse02
for 2 second pulse time
The unit will reply by SMS accordingly to the above as follows:
For example, send:
9999pulse00
The reply will be:
Relay’s function is Momentary Pulse of
½
a second.
7.
How to Check if the Unit’s Relay is ON or OFF
You can check the current status of unit’s relay by SMS command as follows:
*9999 Is the password (default password 9999)
9999relay
The unit will reply by SMS according to the current status of the relay. If the relay is OFF the SMS
reply would be:
The relay is OFF
If the relay is ON the SMS reply would be:
The relay is ON