3.

 

How to Check the Unit’s Current Internal Clock 

To check the local time, date, and weekday in the system, send the following SMS: 

 9999clock 

9999   

Is the password (default password 9999)   

clock   

current internal clock, date and weekdays report. 

 

The unit will reply by SMS that says: 

 The local time is: HH:MM / DD.MM.YYYY, Weekday. 

4.

 

Adding or Deleting “Special Users” 

You can program up to 400 phone numbers as “SPECIAL USERS”. A “SPECIAL USER” is a phone 
number that has limited access during certain times of the day 

and

 is limited to access the 

property on special days of the week.  
 

a.

 

The following SMS message is an example of how to allow an unlimited number of entries 
within a specific timeframe and on certain days of the week for a special user with the 
phone number (041) 831-7452 :   

 9999AS.0418317452.0.0900.1700.127 

9999   

 

Is the password (default password 9999) 

AS 

 

 

Add Special number  

0418317452  

Is the phone number 

 

 

To allow unlimited numbers of entries 

0900.1700   

To limit entries between 9:00AM to 17:00PM 

127   

 

Limiting access to Sundays(1), Mondays(2), & Saturdays(7) 

 
The unit should reply by SMS that says:  

 Confirming: The number 0418317452 allowed unlimited entries on Sundays Mondays     
Saturdays between 9:00AM and 5:00PM 

b.

 

The following SMS message is an example of how to allow a limited number of entries 
with no limit for times or days of the week for a special number:   

 9999AS.0418317435.3.0900.1700.1234567 

9999   

 

Is the password (default password 9999) 

AS 

 

 

Add Special number  

0418317452  

Is the phone number 

 

 

Allow only 3 entries (0-99)   

Summary of Contents for CellOpener-365

Page 1: ...Timer and 365 Day Timer capability to offer maximum security and allow a property manager to prevent a gate or overhead door from opening on certain days and times such as national holidays or specia...

Page 2: ...ite and Blue wires are the internal relay s connections Normally Open N O Com You can select Normally Close N C contact instead of the N O contact of the internal relay by the external jumper in the u...

Page 3: ...d Note There is no need for the dot at the end of the SMS command The maximum phone numbers are 5 phone numbers that can be added or deleted by one SMS command The unit should reply by SMS that says C...

Page 4: ...of how to allow an unlimited number of entries within a specific timeframe and on certain days of the week for a special user with the phone number 041 831 7452 9999AS 0418317452 0 0900 1700 127 9999...

Page 5: ...17 Access limited to Saturdays and Sundays The unit should reply by SMS saying Confirming The number 0418317435 is allowed 3 entries at any time on Sundays and Saturdays Note Please insert 0000 0000 f...

Page 6: ...conds up to 99 seconds Use the following commands to set the pulse time 9999 Is the password default password 9999 9999pulse00 for a second pulse time 9999pulse01 for 1 second pulse time Factory Defau...

Page 7: ...the unit checks the caller s ID the mobile phone number of each incoming call and registers it automatically in the system s memory and at the same time triggers the relay according to the chosen set...

Page 8: ...MAND enables you to overtake control of the system and keep the relay of the unit active ON until cancellation command is received When the unit s relay is in HOLD mode the unit will not respond to an...

Page 9: ...he unit will reply by SMS Open To All is OFF 14 How to Set the Unit to Factory Default Settings To set the unit to Factory Default Settings means the unit will delete all the phone numbers and reset a...

Page 10: ...hat means the GATE is CLOSED and if it is not connected to ground open circuit it means the gate is OPEN To check the status of this input send SMS command as follows 9999 Is the password default pass...

Page 11: ...r this input is The gate was opened You can program the phone number and different messages by sending SMS message as follows 9999AL Phone number _ _ _ Message max 25 characters _ _ _ The following is...

Page 12: ...will turn OFF the relay 17 00PM 127 Representing the days of the week Sunday Monday and Saturday you must put a comma before the next command 0800 The starting time is 08 00AM 1300 The stopping Time i...

Page 13: ...800 0900 23456 0800 1700 17 Second SMS 9999WT2 1500 1600 23456 The unit will confirm by sending SMS with the settings registered in the system Note When the unit s relay is ON active by the weekly tim...

Page 14: ...f accessing the unit on site Note This unit will automatically adjust the local time when daylight saving is due 1 How to set the Yearly Timer The following SMS message is an example of how to set the...

Page 15: ...ered in the System You can get the Yearly Timer report of all the events by sending the following SMS 9999YT report The unit will reply by SMS that says No events are recorded for the Yearly Timer Or...

Reviews: