background image

EMX Industries, Inc. 

Tech support: 216-518-9889 

1/15

 

CellOpener-365_Rev1.0_0601201                      [email protected]

 

 

 

CellOpener-365 

GSM Access Control 
With Yearly & Weekly Timer 

 

Instruction Manual 

 
This GSM access control system allows up to 2000 registered users to operate any garage door / 
gate using their phone with no cost for the call to the user.  This simple to use access control 
system uses a GSM SIM card that must be activated upon installation.  Simply dial the associated 
phone number for the SIM Card from any phone or mobile-phone and the gate will open 
without any cost of a call to you.  The CellOpener-365 also allows for an input contact to be used 
to trigger a SMS text message to a property manager letting them know that someone is at the 
gate or door.   
 
In addition, the unit offers Weekly Timer and 365 Day Timer capability to offer maximum 
security and allow a property manager to prevent a gate or overhead door from opening on 
certain days and times such as national holidays or special events.  The current date and time is 
automatically set via the GSM network so there is never a reason to ever make adjustments for 
daylight savings time.   
 
All programming of the CellOpener-365 occurs using simple SMS text commands.  This feature 
allows programming to be done remotely from anywhere in the world making life easy for 
maintenance, security and HR staffs that need to enable or disable an individual person’s access 
to a site.   
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Power 

12V – 18V AC or DC 

Standby Current–LEDs enabled 
 

0.2A @ 12 VDC / 0.3A @ 24 VDC 

Standby Current-LEDs disabled 

0.1A @12

 VDC / 0.15A @ 24 VDC 

Max Authorized Users 

1600 Normal Users and 400 Special Users 

Relay Contact Rating 

5A @ 24V 

Operating Temperature 

Min -40°C / Max 65°C 

Antenna Cable Length 

1 m (39.4 inches) 

Lead Cable Length 

0.5 m (19.7 inches) 

 

 

Specifications 

Summary of Contents for CellOpener-365

Page 1: ...Timer and 365 Day Timer capability to offer maximum security and allow a property manager to prevent a gate or overhead door from opening on certain days and times such as national holidays or specia...

Page 2: ...ite and Blue wires are the internal relay s connections Normally Open N O Com You can select Normally Close N C contact instead of the N O contact of the internal relay by the external jumper in the u...

Page 3: ...d Note There is no need for the dot at the end of the SMS command The maximum phone numbers are 5 phone numbers that can be added or deleted by one SMS command The unit should reply by SMS that says C...

Page 4: ...of how to allow an unlimited number of entries within a specific timeframe and on certain days of the week for a special user with the phone number 041 831 7452 9999AS 0418317452 0 0900 1700 127 9999...

Page 5: ...17 Access limited to Saturdays and Sundays The unit should reply by SMS saying Confirming The number 0418317435 is allowed 3 entries at any time on Sundays and Saturdays Note Please insert 0000 0000 f...

Page 6: ...conds up to 99 seconds Use the following commands to set the pulse time 9999 Is the password default password 9999 9999pulse00 for a second pulse time 9999pulse01 for 1 second pulse time Factory Defau...

Page 7: ...the unit checks the caller s ID the mobile phone number of each incoming call and registers it automatically in the system s memory and at the same time triggers the relay according to the chosen set...

Page 8: ...MAND enables you to overtake control of the system and keep the relay of the unit active ON until cancellation command is received When the unit s relay is in HOLD mode the unit will not respond to an...

Page 9: ...he unit will reply by SMS Open To All is OFF 14 How to Set the Unit to Factory Default Settings To set the unit to Factory Default Settings means the unit will delete all the phone numbers and reset a...

Page 10: ...hat means the GATE is CLOSED and if it is not connected to ground open circuit it means the gate is OPEN To check the status of this input send SMS command as follows 9999 Is the password default pass...

Page 11: ...r this input is The gate was opened You can program the phone number and different messages by sending SMS message as follows 9999AL Phone number _ _ _ Message max 25 characters _ _ _ The following is...

Page 12: ...will turn OFF the relay 17 00PM 127 Representing the days of the week Sunday Monday and Saturday you must put a comma before the next command 0800 The starting time is 08 00AM 1300 The stopping Time i...

Page 13: ...800 0900 23456 0800 1700 17 Second SMS 9999WT2 1500 1600 23456 The unit will confirm by sending SMS with the settings registered in the system Note When the unit s relay is ON active by the weekly tim...

Page 14: ...f accessing the unit on site Note This unit will automatically adjust the local time when daylight saving is due 1 How to set the Yearly Timer The following SMS message is an example of how to set the...

Page 15: ...ered in the System You can get the Yearly Timer report of all the events by sending the following SMS 9999YT report The unit will reply by SMS that says No events are recorded for the Yearly Timer Or...

Reviews: