KPX 100 Instuctions.doc Rev 1.6 7/10//2018
7 0
7 1
7 2
7 6
5 to 10
00
#
#
#
#
After 10 successive false codes, keypad will lock
for 30 seconds
After 10 successive false codes, the Duress output
switches to ground
Selectable from 5 to 10 successive false codes, the
keypad locks for 15 minutes. The keypad can be
reset to release lock with the Master Code at any
time during the locking period.
Removal of all above security settings
8 0
8 0
#
#
1
0
Door Forced Open Alarm is Activated
Door Forced Open Alarm is Disabled
8 1
1
#
1 second notification beep is given to notify the
person outside to open the door when output
relay is activated with a user code or egress
button. Good for the locking device that gives no
sound when it activates, such as magnetic lock.
8 1
0
#
Notification beep disabled and replaced by 2
short successful code entry beeps for valid
user codes.
8 2
1
#
Auto Entry Mode is selected. Key that follows
the user code is not required in code entry. The user
codes must be set in the same digit length as the
Master Code in Auto Entry mode and the code can be
4-8 digits
8 2
0
#
Manual Entry Mode is selected. Key that follows
the user code is required in code entry. The user codes
can be 4-8 digits and are not required to be the same
length as the Master Code.
#
#
Pg 7
Summary of Contents for KPX 100
Page 2: ...KPX 100 Instuctions doc Rev 1 6 7 10 2018...
Page 3: ...KPX 100 Instuctions doc Rev 1 6 7 10 2018...
Page 6: ...KPX 100 Instuctions doc Rev 1 6 7 10 2018 Pg 3 D A P Reset see Page 5...
Page 7: ...KPX 100 Instuctions doc Rev 1 6 7 10 2018 Pg 4...
Page 12: ...KPX 100 Instuctions doc Rev 1 6 7 10 2018 MASTER CODE 8 9 0 0 MASTER CODE 8 9 0 1 Pg 9...
Page 19: ...KPX 100 Instuctions doc Rev 1 6 7 10 2018 Pg 16...
Page 21: ...KPX 100 Instuctions doc Rev 1 6 7 10 2018 Pg 18...
Page 22: ...KPX 100 Instuctions doc Rev 1 6 7 10 2018 Pg 19...