9.0 ELC Custom Device Settings
The following settings are available to control the ELC. These settings get applied to
ALL
ELC
devices connected on the CAN bus.
1.
Reset CAN IDs to Default
2.
Enable Heater Override (See Section 5.0)
3.
Enable EMAP (See Section 6.0)
4.
ELC Heater RPM Lockout (See Section 5.0)
5.
ELC Heater Post Start Lockout (See Section 5.0)
6.
ELC Lambda 1 Test Enable
7.
ELC Lambda 2 Test Enable
These settings are available from the Config View -> Communications Tab -> Emtron CAN
Device -> Emtron Lambda to CAN (ELC/ELCM) Setup". See Figure 9.0
Figure 9.0
The ELC Lambda 1 and 2 Test Enable setting will force the ELC device to send the Test
Lambda value over the CAN bus. The ECU will read that value and
it’s
a simple way of
confirming the system is calibrated correctly. Make sure this setting is reset back to zero
when finished.
NOTE:
When any custom ELC setting is changed, the setting is automatically stored by the
ELC device and therefore used on the next power cycle.