S electaCell®

M ounting Instructions

Step 1: Feed Power Cord through
            M ounting A dapter

S tep 2: A ttach Pow er P lug to Pow er
             Jack on SelectaCell® and
             attach M ounting A dapter
             using 2 S crew s provided

S tep 3: A ttach Mounting Base to
            suitable surface using
            S crew s and Anchors as
            necessary

Step 4: S lide SelectaCell® with
             M ounting Adapter onto
             M ounting Base and route
             P ower Cord through
             Channel in M ounting B ase.
             S lide Cover onto M ounting
             B ase.

Mounting Adapter

Power Cord

Power P lug

P ow er  Jack

M ounting Base

S crew

Anchor

Screw

Mounting Base

Cover

Pow er Cord

Channel

Switch

USB Port

Mounting Base

Power Supply

Plug

Display

4.0 Primary 

Power 

 
The SelectaCell® operates on 7.5 VDC input power @ 0.7 Amp.  This unit is supplied with a regulated 
wall mount power supply, which is UL, and CSA listed and will operate on AC input voltage of 90-240 
VAC. 
 

5.0 Donor/Server 

Antenna 

 
Internal donor and server antennas have 13 dB and 10dB gain, respectively.   The donor antenna must 
be orientated to point in the direction of the Service Providers cell site location, but does not necessarily 
have to point exactly at the cell site.   The indicators will provide a reference of the strongest RF power 
strength when the antenna is located in the optimum location. 
 

6.0 Installation: 

 

Note 1:  The user is cautioned that modification or changes to this device not expressly approved by the 
party responsible for compliance could void the user’s authority to operate this equipment. 
 
Note 2: Manufacturer’s rated composite output power, individual channel power will vary depending on 
the number of channels and distance from each cell site being received 
 
Note 3:  This device complies with Part 15 of the FCC Rules.  Operation is subject to the condition that 
this device does not cause harmful interference. 
 

 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Note

:  

Assemble foot support on unit 

to check setup prior to installing and 
firming attaching with bottom screws to 
window sill.

.

Summary of Contents for SelectaCell-19S

Page 1: ...70 831 8598 FCC Part 24 Transmitter Certification Test Report FCC ID DNY0B2SCELL1900 FCC Rule Part CFR 47 Part 24 Subpart E ACS Report Number 05 0272 24E Manufacturer EMS Wireless Equipment Type PCS Band Bi Directional Amplifier Model SelectaCell 19 S Operators Manual ...

Page 2: ...IM609873 1 Rev 01 07 11 05 SelectaCell 19S OPERATOR S MANUAL Preliminary 1900 MHz BAND SELECT INDOOR REPEATER 2850 Colonnades Court Norcross GA 30071 U S A Tel 770 582 0555 Fax 770 729 0075 ...

Page 3: ......

Page 4: ... effective pricing 2 0 Functionality The SelectaCell is capable of automatically adjusting its own signal gain levels up to the maximum output power levels SelectaCell detects the downlink output power and adjusts the level for 12 dBm EIRP composite output power and continues to monitor and reset the gain as required for proper system performance For example when CDMA protocol is being amplified t...

Page 5: ...and CSA listed and will operate on AC input voltage of 90 240 VAC 5 0 Donor Server Antenna Internal donor and server antennas have 13 dB and 10dB gain respectively The donor antenna must be orientated to point in the direction of the Service Providers cell site location but does not necessarily have to point exactly at the cell site The indicators will provide a reference of the strongest RF power...

Page 6: ...to automatically optimize set up and will improve performance in most applications as long as a signal can be received at a window Actual area of coverage that will be improved will vary depending on the signal level received and blockage Placement of the unit The SelectaCell unit should be located in a window where the user s service provider has enough coverage to initiate a call For best result...

Page 7: ... the greatest signal strength 1 Using a subscriber unit cell phone and monitoring the signal strength indicators number of bars displayed on the phone check each window location The window location that has the most displayed bars should be the location selected Place the unit on the windowsill or on a counter or nearby table top or other convenient location with the LCD display facing indoors Not...

Page 8: ...htly while observing the bars for maximum signal strength 8 Once unit position is complete hard power recycle by manually disconnecting and reconnecting AC power This will allow the unit to automatically set up on the new band assignment Important This step must be performed to save the selected band B SelectaCell Setup Instruction through USB Setup instructions via the USB port and requiring a co...

Page 9: ...ation software is loaded proceed to the next step 6 At this time using a 7 5Vdc power supply and apply power to the SelectaCell 7 After applying power to the connected SelectaCell the USB timeout indication will automatically clear and the indicator should switch from flashing red to solid green on the Identity screen a Select Get and this screen will also display the Firmware Revision Model Seria...

Page 10: ... and select the appropriate box for By Center Frequency ii Select the requested Bandwidth filter size of either 5 MHz or 15 MHz iii Input the 4 digit PCS downlink frequency and Uplink the uplink frequency will appear e Verify input downlink and uplink frequency f After selecting the correct frequencies save by selecting the Set button with a mouse click g Next to activate and store this informatio...

Page 11: ...nary version of the SelectaCell application has 3 menu tabs that can be selected from the top portion of the application Screenshots and explanations of the menus are as follows Identity Startup Screen Screen A Identity screen displays SelectaCell unit version Model Serial and PCB Serial Number plus any error status indicators These are stored in non volatile flash on the SelectaCell hardware and ...

Page 12: ...t the frequency tab and select the appropriate PCS band or sub band with a mouse click Activate the Set button with a mouse click to setup either by the desired band in the SelectaCell or input the center frequency for the downlink and the uplink will automatically display Activate the Set button with a mouse click to store this band in the SelectaCell Note if Set is not activated the unit will st...

Page 13: ... Information IM609873 1 Rev 01 07 11 05 12 Control Screen Screen C Displays downlink and uplink output power and gain and is used to restart the SelectaCell after selecting a new frequency band After selecting the PCS band in the previous frequency screen activate Restart button with a mouse click initiate automated setup ...

Page 14: ... a Class B digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications...

Page 15: ...NING until described conditions are fully understood and met If You Need Help If you need additional copies of this manual or have questions about system options or need help with installation and using of the system please contact EMS Wireless Customer Support EMS Wireless Customer Support 2850 Colonnades Court NW Norcross GA 30071 1 770 582 0555 x 5310 email cs wireless ems t com Service Do not ...

Page 16: ...ranty period This warranty is the only warranty made by EMS Wireless and is in lieu of all other warranties expressed or implied except as to title and can be amended only by a written instrument signed by an officer of EMS Wireless EMS Wireless sales agents or representatives are not authorized to make commitments on warranty returns In the event that it is necessary to return any product against...

Page 17: ...UT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE EMS WIRELESS SHALL NOT BE LIABLE FOR ANY OTHER DAMAGE INCLUDING BUT NOT LIMITED TO INDIRECT SPECIAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH FURNISHING OF GOODS PARTS AND SERVICE HEREUNDER OR THE PERFORMANCE USE OF OR INABILITY TO USE THE GOODS PARTS AND SERVICE EMS Wireless test r...

Page 18: ...SelectaCellTM Operator s Manual Preliminary EMS Wireless EMS Wireless SelectaCell 19S Manual Confidential and Proprietary Information IM609873 1 Rev 01 07 11 05 17 ...

Page 19: ...SelectaCellTM Operator s Manual Preliminary EMS Wireless EMS Wireless SelectaCell 19S Manual Confidential and Proprietary Information IM609873 1 Rev 01 07 11 05 18 ...

Page 20: ...rator s Manual Preliminary EMS Wireless EMS Wireless SelectaCell 19S Manual Confidential and Proprietary Information IM609873 1 Rev 01 07 11 05 19 2850 Colonnades Court Norcross GA 30071 PH 770 582 0555 FAX 770 729 0075 ...

Reviews: