Thermostats are not approved on vented decorative
appliances.
Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation. Verify
proper operation after servicing.
18", 24" and 30" gas appliance (Millivolt) thermopile self powers
the gas valve and does not require 110 volts. See Figure 16 to
provide optional wall switch, thermostat, or remote control.
Maximum length of 20 feet of 16 AWG conductor wires should
be used with all optional switches.
Check System Operation
Millivolt system and all individual components may be checked
with a millivolt meter 0-1000 MV range.
Remote Receiver
Use the following steps to place the
remote receiver
to the burner
base assembly.
Attention:
1. The remote receiver
can not
be placed behind or inside the
gas burner assembly. The remote receiver should be located
outside of the firebox.
2. The remote receiver must be placed away from the gas
appliance base. The receiver can be placed under the burner
assembly in a lower air moving compartment of a fireplace
or firebox, installed in a wall mounted junction box, or set on
the hearth extension.
Note:
Do not let remote control receiver come in contact with the
top of the appliance.
On a circulating vent-free firebox, it may be possible to install the
remote control receiver behind the bottom operable louver.
Refer to remote control installation and operating instructions for
more details on remote control.
750 Millivolt System
When you ignite the pilot, the thermocouple produces millivolts
(electrical current) which energizes the magnet in the gas valve.
After 30 seconds to 1 minute time period you can release the gas
control knob and the pilot will stay ON. Allow your pilot flame to
operate an additional one (1) to two (2) minutes before you turn the
gas control knob from the PILOT position to the ON position. This
time period allows the millivolts (electrical current) to buildup to a
sufficient level allowing the gas control to operate properly.
Millivolt Control
The valve regulator controls the burner pressure which should be
checked at the pressure test point. Turn captured screw counter
clockwise 2 or 3 turns and then place tubing to pressure gauge over
test point (Use test point “A” closest to control knob). After taking
pressure reading, be sure and turn captured screw clockwise firmly
to re-seal. Do not over torque. Check for gas leaks.
!
"
#$
#$
#$
#$
#$
#$
#$
!
#$
WIRING - VFRL MODELS
Figure 16
Summary of Contents for VFIL18N
Page 1: ......
Page 33: ...26532 2 0410 Page 33 VFIL PARTS VIEW...
Page 35: ...26532 2 0410 Page 35 VFRL PARTS VIEW...
Page 37: ...26532 2 0410 Page 37 SERVICE NOTES...
Page 38: ...26532 2 0410 Page 38 SERVICE NOTES...
Page 39: ...26532 2 0410 Page 39 SERVICE NOTES...
Page 40: ......