background image

32274-7-1014

Page 24

EMPIRE

EMPIRE

Comfort Systems

Empire Comfort Systems Inc.

918 Freeburg Ave. Belleville, IL  62220

If you have a general question about our products, please e-mail us at 

[email protected]

If you have a service or repair question, please contact your dealer.

www.empirecomfort.com

Summary of Contents for OLP36FP72S(N

Page 1: ...formation in these instructions are not fol lowed exactly a fire or explosion may result causing property damage personal injury or loss of life WARNING Improper installation adjustment alteration ser...

Page 2: ...n 10 11 Fireplace Framing and Installation 12 13 Gas Line Connection 13 Operation Instructions Flame Appearance 14 OLP 36 42 FP72 Lighting Instructions 15 Main Burner Flame Characteristics 16 Wiring 1...

Page 3: ...to the ap pliance being into operation if there is evidence of ex cessive abrasion or wear or if the hose is damaged Inspect the burner at least once a year IMPORTANT SAFETY INFORMATION DO NOT OPERATE...

Page 4: ...as can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a clos...

Page 5: ...as Field conversion is not permitted Instructions to Installer 1 Installer must leave instruction manual with owner after installation 2 Installer must have owner fill out and mail warranty card suppl...

Page 6: ...the enclosure shall be completely open or b For an enclosure having four sides a top and a bottom 1 At least two ventilation openings at cylinder valve level shall be provided in the side wall equall...

Page 7: ...manual gas cock A manual main gas cock should be located in the vicinity of the unit Where none exists or where its size or location is not adequate contact your local authorized installer for instal...

Page 8: ...ss fireplace models must use the hood supplied with the fireplace If a combustible mantel is installed it must meet the clearance requirements detailed in Figure 2 Figure 2 Mantel Clearances CLEARANCE...

Page 9: ...nches REFERENCE LETTER OLP36FP OLP42FP A 42 1 8 42 1 8 B 41 3 4 45 3 4 C 19 1 4 19 1 4 D 32 1 4 36 1 4 E 34 7 8 34 7 8 F 36 40 G 24 24 H 6 3 8 6 3 8 I 30 3 8 30 3 8 J 8 3 8 8 3 8 K 5 1 4 5 1 4 L 37 5...

Page 10: ...pliance has become increas ingly popular however the area above any appliance gets hot and most TV manufacturers recommend against placing their products near a heat source If you install a television...

Page 11: ...develop some surface oxidation rust This does not affect the performance of the fireplace and does not require any action to correct If you prefer keeping your fireplace front looking factory fresh cl...

Page 12: ...e the bracket under the screw as shown in Figure 11 Tighten the hex head screws on the fireplace secure a pan head screw through the middle bracket and into the top stud 4 Slide the fireplace into pos...

Page 13: ...r for proper model Always use an external regulator for all LP fireplaces to reduce the supply tank pressure to a maximum of 14 w c This is in addition to the regulator fitted to the log set WARNING C...

Page 14: ...ors remaining after this initial break in will be slight and will disappear with continued use PERIODIC CLEANING Refer to parts diagram for location of items discussed below Do not use cleaning fluid...

Page 15: ...the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE 1 Locate On Off gas cock and turn clockwi...

Page 16: ...ck from instruction enve lope package 2 Slide battery cover plate off of battery pack insert batteries ensure correct polarity and replace battery cover plate 3 Connect red wire from battery pack to r...

Page 17: ...l use if batteries are replaced or if a replacement transmitter is purchased from your dealer or the factory In order for the module to accept the transmitter security code be sure the slide button on...

Page 18: ...ontrol knob to LOW position and let warm up for a minute b Air in gas line Operate burner until air is removed from line Have gas line checked by local gas company c Dirty or partially clogged burner...

Page 19: ...anty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Numbe...

Page 20: ...3 Connector Male 5 16 X 3 8 NPT 18 28089 28089 Valve Shield 19 P212 P212 Orifice Fitting 20 P209 P209 Orifice Nat 20 P245 P265 Orifice LP 21 28111 28111 Module Shield 22 28739 28740 Burner Welded Asse...

Page 21: ...32274 7 1014 Page 21 PARTS VIEW 13 13 14 4 6 5 2 16 20 19 22 18 24 31 28 35 12 29 33 15 21 25 17 36 1 1 38 39 3 37 37 7 7 40 41 40...

Page 22: ...32274 7 1014 Page 22 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Page 23: ...A bill of sale cancelled check or payment record should be kept to verify purchase date and establish warranty period Ready access to the appliance for service What Is Not Covered Damages that might r...

Page 24: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Reviews: