Introduction

Always consult your local Building Department regarding regula-

tions, codes or ordinances which apply to the installation of a direct 

vent wall furnace.

Instructions to Installer

1.  Installer must leave instruction manual with owner after instal-

lation.

2.  Installer must have owner fill out and mail warranty card sup

-

plied with furnace.

3.  Installer should show owner how to start and operate furnace 

and thermostat.

Warning:

Any change to this furnace or its control can be dangerous.  

This is a heating appliance and any panel, door or guard 

removed for servicing an appliance must be replaced prior 

to operating the appliance.

To Conserve Gas: Turn off pilot when heater is not in use.

General Information

This furnace is design certified in accordance with American National 

Standard/CSA Standard Z21.86 and CSA 2.32 by the Canadian 

Standards Association,  as a fan type direct vent wall furnace to be 

installed according to these instructions.

Any alteration of the original design, installed other than as 

shown in these instructions or use with a type of gas not 

shown on the rating plate is the responsibility of the person 

and company making the change.
Important

All correspondence should refer to complete Model No., Serial No. 

and type of gas.

Notice

:  During initial firing of this unit, its paint will bake out  and 

smoke will occur.  To prevent triggering of smoke alarms, ventilate 

the room in which the unit is installed.

Installation on Rugs and Tile

If this appliance is installed directly on carpeting, tile or other 

combustible material other than wood flooring the appliance shall 

be installed on a metal or wood panel extending the full width and 

depth of the appliance.  

The base referred to above does not mean the fire-proof base as 

used on wood stoves.  The protection is for rugs that are extremely 

thick and light colored tile.

Installation in Residential Garages

Gas utilization equipment in residential garages shall be installed 

so that all burners and burner ignition devices are located not less 

than 18" above the floor.

Such equipment shall be located, or protected, so it is not subject 

to physical damage by a moving vehicle.  

Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equip-

ment or accessories and repair and servicing of equipment shall 

be  performed  only  by  a    qualified  agency.    The  term  "qualified 

agency" means any individual, firm, corporation or company which 

either in person or through a representative is engaged in and is 

responsible for (a) the installation or replacement of gas piping or 

(b) the connection, installation, repair or servicing of equipment, who 

is experienced in such work, familiar with all precautions required 

and has complied with all the requirements of the authority having 

jurisdiction.

State of Massachusetts:

 The installation must be made 

by  a  licensed  plumber  or  gas  fitter  in  the  Commonwealth  of 

Massachusetts.

The installation must conform with local codes or, in the absence of 

local codes, with the 

National Fuel Gas Code ANSI  Z223.1/NFPA 

54* Natural Gas and Propane Installation Code, CSA B149.1.

*Available from the American National Standards Institute, Inc., 11 

West 42nd St., New York, N.Y. 10036.

High Altitudes

For altitudes/elevations above 2,000 feet, input ratings should be 

reduced at the rate of 4 percent for each 1,000 feet above sea level.  

Canadian High Altitudes 

for locations having an elevation above 

mean sea level between 2,000 feet (610m) and 4,500 feet (1370m), 

the manifold pressure is to be decreased from 4.0" w.c. to 3.2" w.c. 

for Natural Gas and from 10.0" w.c. to 8.0" w.c. for Propane Gas.

Piezo Pilot Ignitor Instructions

Depressing the red button completely causes a spark to occur at 

the pilot. This is a substitute for a match which requires opening 

the pilot hole cover.
To light the pilot, it is important that the electrode be 1/8" from the 

thermocouple. The spark must occur at the point the burner flame 

hits the thermocouple. The end of the electrode will be red hot with 

the pilot on.
On a new installation with air in the gas line, it is suggested that a 

match be used. The match will light the pilot faster than the piezo 

under this condition.

Model

DV-55SPP

Input BTU/HR

55,000

Height

82 3/8"

Width

16"

Depth

11 1/2"

Gas Inlet

1/2" Pipe

CFM

400

Accessories

SOR-1

Register Side Outlet

SOK-1

Side Outlet Kit, 10" Boot Assembly with Register

DV-822

Vinyl Siding Vent Kit

INTRODUCTION

SPECIFICATIONS

Summary of Contents for DV-55-1SPP

Page 1: ...h can cause death or serious illness Installer Leave this manual with the appliance Consumer Retain this manual for future reference WARNING If the information in these instructions are not followed e...

Page 2: ...duction 6 Specifications 6 Gas Supply 7 8 Clearances 8 Installation Instructions 9 11 Lighting Instructions 12 Pilot Flame Characteristics 13 Main Burner Flame Characteristics 13 Wiring 14 Service and...

Page 3: ...The appliance should be inspected before use and at least annually by a qualified service person More frequent cleaning may be required due to excessive lint from carpet ing bedding materials etc It i...

Page 4: ...gas can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a clo...

Page 5: ...oxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 3 SIGNAGE A metal or plastic identification plate shall be pe...

Page 6: ...it is not subject to physical damage by a moving vehicle Qualified Installing Agency Installation and replacement of gas piping gas utilization equip ment or accessories and repair and servicing of e...

Page 7: ...local authorized installer for installation or relocation Compounds used on threaded joints of gas piping shall be resistant to the action of liquefied petroleum gases The gas lines must be checked f...

Page 8: ...distance from the center of the vent cap to the nearest outside corner or obstruction is 24 inches CLEARANCES Checking Manifold Pressure Both Propane and Natural gas valves have a built in pressure re...

Page 9: ...provided Side outlet kit 10 boot assembly with register SOK 1 for warm air discharge into an adjoining room may be installed on either side of the furnace at the required clearance of 4 inches to adj...

Page 10: ...ove old furnace cement from both ends of 4 diameter flue outlet tube 3 Attach 6 diameter air inlet tube onto the collar of air drop assembly Attach caulked outside mounting plate into the 6 diameter a...

Page 11: ...e projection 2 x 4 framing whose outside dimensions match the overall dimensions of the mounting plate is recommended The 2 x 4 framing protects siding from possible warpage or discoloration All joint...

Page 12: ...5 Set thermostat to desired setting if applicable FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage pe...

Page 13: ...emovingthe burner door from the combustion chamber remove rear burner pilot burner and front burner With front and rear burners removed from furnace force water into the ribbon ports and dry with air...

Page 14: ...receptacle and its wire connected to the receptacle mounting screw With this wire completing the ground the appliance cord plug can be plugged into the adapter and be electrically grounded A 7 8 hole...

Page 15: ...e is first installed or was off all summer the pilot flame may be too lean to ignite on the first few trials Turn the control valve knob to pilot position and depress the red reset button Holding the...

Page 16: ...l Gas 28 DV808 Pilot Tubing 29 DV824 Front Burner 30 P8842 Main Burner Orifice Natural Gas Two Required 30 P8853 Main Burner Orifice LP Gas Two Required 31 DV687 Manifold and Plate Assembly 32 M148 Ma...

Page 17: ...Page 17 32188 4 0814 PARTS VIEW...

Page 18: ...ranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Numb...

Page 19: ...A bill of sale cancelled check or payment record should be kept to verify purchase date and establish warranty period Ready access to the appliance for service What Is Not Covered Damages that might r...

Page 20: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Page 21: ...aladies Ne pas entreposer ni utiliser d essence ni d autres vapeurs ou liquides inflammables dans le voisnage de cet appareil ou de tout autre appareil QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas...

Page 22: ...st chaud lorsque le radiateur est en fonction L installation et la r paration doivent tre faites par une per sonne qualifi e L appareil doit tre inspect avant l usage et au moins une fois par ann e pa...

Page 23: ...bas Attendez que les pompiers vous assurent de la s ret de ces endroits avant d y aller Utiliser le t l phone de votre voisin et appeler les pompiers et une personne entra n e avec le propane Ne pas...

Page 24: ...e gaz d entrer par le capuchon de l vent Emplacement de l Ouverture dans le Mur Le radiateur doit tre situ sur un mur ext rieur Trouver les montants du mur ainsi l ouverture dans le mur sera entre les...

Page 25: ...D ESPACE LIBRE AUX MAT RIAUX COMBUS TIBLES VENANT DU D GAGE MENT DU REGISTRE DE CHAQUE C T ENTR E DE GAZ ENLEVER PLINTHE ET MOULURE OUVERTURE D VENT 7 1 2 19cm MUR AR RI RE MINIMUM D ESPACE LIBRE AU C...

Page 26: ...l entr e de la pluie Attacher la plaque ext rieure de montage au mur ext rieur avec 4 vis 10 x 1 38mm Les vis sont fournies 4 Appliquer du ciment pour radiateur au collet de la sortie Emplacement de l...

Page 27: ...ourrev tementnedoitpasexc derune paisseur totale de 13 33 02cm pour le DV 55 voir Figure 5a AVERTISSEMENT Lorsque l ensemble d vent pour le rev tementenvinyleDV 822oulaconstructionfaitede2 x 4 5 08cm...

Page 28: ...x et de raccords en m tal ondul ANS Z21 45 Connexions flexibles d appareil autre qu en m tal Les connexions ci dessus peuvent tre utilis es si elles sont accept es par les autorit s ayant juridiction...

Page 29: ...index no 4 pi ce no 712059 Les joints d tanch it doivent tre tir s pour s adapter sur les boulons du moteur dans les espaces pour joint d tanch it Le moteur et les joints d tanch it peuvent tre instal...

Page 30: ...iliserseulement votre main pourpousserou tournerle bouton de contr le de gaz N utiliserjamais des outils Si vousnepouvezpaspousseroutournerleboutonavecvos mains n essayerpasdeler parer appeleruntechni...

Page 31: ...a veilleuse et r allumer La veilleuse s enflamme mais s teint lorsque le bouton est rel ch 1 Suivre les instructions et appuyer sur le bouton plus long temps et fermement 2 D terminer si la flamme de...

Page 32: ...semblage du br leur avant 30 P8842 Br leur principal avec ouverture gaz naturel exige deux 30 P8853 Br leur principal avec ouverture gaz propane exige deux 31 DV687 Tuyau de gaz et assemblage de plaqu...

Page 33: ...Page 13 32188 4 0814 Empire Comfort Systems Inc Nine Eighteen Freeburg Ave Belleville Illinois 62220 2623...

Page 34: ...ificatif de paiement pour attester de la date d achat et tablir la p riode de garantie Acc s imm diat l appareil pour la r paration Ce qui n est pas couvert Dommages pouvant r sulter de l emploi de l...

Page 35: ...Page 15 32188 4 0814 NOTES DE SERVICE...

Page 36: ...Systems Inc 918 Freeburg Ave Belleville IL 62220 Pour toute question g n rale concernant nos produits veuillez nous envoyer un courriel info empirecomfort com Pour toute question d entretien ou de r...

Reviews: