background image

35467-2-1015

Page 4

1

9

14

2

3

4

5

6

8

10

11

12

13

15

16

17

7

INDEX 

NO.

PART 

NO.

DESCRIPTION

QUANTITY

HEATED TRAY ASSEMBLY

1

35468

Condensate Tray Box

1

2

32181

Condensate Tray Bracket

1

3

32330BL

Porcelain Condensate Tray

1

4

32342

Insulation Pad

1

5

R11700

Heating Element

1

6

R11707

Sensing Screw, 8-32 x 5/8

1

7

R11708

Sensing Screw, 8-32 x 1

2

8

R11709

Limit Switch

1

9

R12040

Condensate Tray Harness

1

RELAY ASSEMBLY

10

32185

Relay Bracket

1

11

32012

Condensate Tube Bracket

1

12

R11701

Relay Heating Element

1

13

32182

Condensate Tube Bracket

1

14

R12041

Relay Harness

1

15

R11702

3/8 Rubber Grommet

1

HARDWARE

16

R2737

#10 x 1/2 Hex Head Screw

4

17

R11594

Hose Clamp - 5/8

1

NOTE:

 Items not shown to scale.

BLK

WHT

BLK/YEL

WHT/YEL

BLK

WIRING

HARNESS

CONNECTOR

120 VAC RELAY

120 VAC

LOW VOLTAGE

LIMIT

SWITCH

HEATING ELEMENT

WATER

LEVEL

SENSOR

BLK

WHT

WHT

RED

BLK

WHT

RED

BLK

WHT/YEL

BLK/YEL

WIRING DIAGRAM

www.empirecomfort.com

Empire Comfort Systems Inc.

Belleville, IL

If you have a general question 

about our products, please e-mail 

us at [email protected]
If you have a service or repair 

question, please contact your dealer.

Summary of Contents for PVSHT2-1

Page 1: ...Carefully remove the front cover of the wall furnace by lifting up and pulling out 2 Turn off the main power switch Or unplug the wall furnace power cord from the wall outlet See Figure 1 Figure 1 3...

Page 2: ...wdriver into the slots on the condensate tray bracket to level the tray from front to back and side to side Verify with a small level Tighten the front mounting screws when level Make sure the heated...

Page 3: ...be into the black condensate hose attached to the condensate trap Use the pliers to move the hose clamp to the portion of the condensate hose which is over the condensate tube See Figure 10 Figure 10...

Page 4: ...Tube Bracket 1 12 R11701 Relay Heating Element 1 13 32182 Condensate Tube Bracket 1 14 R12041 Relay Harness 1 15 R11702 3 8 Rubber Grommet 1 HARDWARE 16 R2737 10 x 1 2 Hex Head Screw 4 17 R11594 Hose...

Page 5: ...le couvercle avant de la chaudi re murale en le soulevant et en le tirant 2 teignez l interrupteur principal Ou d branchez le cordon d alimentation de la fournaise murale de la prise murale Voir Figu...

Page 6: ...sats pour niveler le bac d avant en arri re et d un c t l autre V rifiez avec un petit niveau Serrez les vis de montage avant lorsqu elles sont de niveau Assurez vous que le plateau chauffant ne repos...

Page 7: ...u de condensat noir fix au pi ge condensat Utilisez la pince pour d placer le collier de serrage sur la partie du tuyau de condensat qui se trouve au dessus du tube de condensat Voir Figure 10 Figure...

Page 8: ...32182 Support de tube de condensat 1 14 R12041 Harnais de relais 1 15 R11702 Oeillet en caoutchouc 3 8 1 MAT RIEL 16 R2737 Vis t te hexagonale n 10 x 1 2 4 17 R11594 Collier de serrage 5 8 1 Remarque...