35467-3-0320
Page 1
Empire Comfort Systems Inc. • Belleville, IL
PVSHT2-1 HEATED HUMIDIFICATION TRAY. FOR USE ON: PVS(18,35)(N,P)-2
INSTRUCTIONS MUST BE LEFT WITH THE OWNER FOR FUTURE REFERENCE AFTER INSTALLATION.
TOOLS NEEDED:
•
1/4" Nut Driver
or Socket
•
Pliers
•
Side Cutter
•
5/16" Nut Driver
10"+ Long or Socket
With Extension
•
Small level
WARNING
ELECTRICAL SHOCK HAZARD! Disconnect all electrical
power to the wall furnace prior to servicing.
INSTALLATION
1. Carefully remove the front cover of the wall furnace by lifting
up and pulling out.
2. Turn off the main power switch. Or unplug the wall furnace
power cord from the wall outlet.
See Figure 1.
Figure 1
3. Remove the lower louver assembly by removing the four (two
each side) hex head screws fastening the louvers to the outer
cabinet with the 5/16 nut driver.
4. If wall furnace has been installed and operated, the condensate
trap must be drained. Disconnect the clear hose from the front
inducer tap and use to drain the condensate from the tap into
a cup. Replace the line when done.
See Figure 2.
Figure 2
OWNER’S MANUAL
AND INSTALLATION
INSTRUCTIONS