background image

37410-0-0616

Page 15

Numéro 

d’index 

Numéro 

de la pièce 

Description

1

WFA-115

Joint d’étanchéité du collecteur

2

36324

Ensemble collecteur (inclus No. 1, joint 

d’étanchéité) 

3

GWT-184

Ensemble des parois intérieures 

4

GWT-151

Ensemble du coupe-tirage (exige 2)

5

GWT-020

Blindage à l’avant (exige 2) 

6

GWT-077

Blindage thermique (exige 2)

7

36328

Façade d’enveloppe (exige 2) 

(Comprend deux n°11)

8

GWT-186

Support des parois (exige 4) 

9

36321

Ensemble des portes (exige 2)

10

R-885

Rondelle en nylon (exige 4)

11

R-3763

Aimant (exige 4)

12

DV-064

Plaque de recouvrement (exige 2) 

13

GWT-008

Compartiment avant du brûleur - (exige 

2) 

14

R-3046

Interrupteur de sûreté de l’évent

15

R-3038

Ensemble de conducteur eco

16

26466

Ensemble de l’échangeur - arrière

17

26465

Ensemble de l’échangeur - avant

18

R-3036

Veilleuse  - NAT

18

R-3037

Veilleuse  - PL

19

R-1054

Thermopile

20

GWT-096

Ensemble du support du brûleur

21

R-5245

Soupape de gaz - NAT

21

R-5246

Soupape de gaz - PL

 utiliser seulement les pièces de remplacement du fabricant.  l’emploi de d’autres pièces peut causer des blessures ou la mort.

attentIon

: Lorsque vous commandez les pièces, il est très important que le numéro de la pièce et la description coïncident.

Les pièces peuvent être commandées seulement par l’entremise du 

technicien d’entretien ou du vendeur.

  Pour de meilleurs résultats, le 

technicien d’entretien ou le vendeur 

devrait commander les pièces chez le distributeur.  Les pièces peuvent être expédiées directement 

au technicien d’entretien ou au vendeur.
Toutes les pièces énumérées dans la liste ont un numéro de pièce.  Lorsque vous commandez des pièces, premièrement obtenez le numéro 

du modèle sur la plaque d’identification de l’appareil. Puis en vous référant à l’illustration et à la liste des pièces, déterminer le numéro 

de la pièce (pas le numéro d’index) et la description de chaque pièce.  Soyez certain de donner toutes ces informations.
Numéro du modèle du radiateur 

  Description de la pièce 

Numéro de série du radiateur 

  Numéro de la pièce 

Sorte de Gaz (Propane ou Naturel) 
Ne pas commander les boulons, les vis, les rondelles ou les écrous.  Ce sont des pièces standard que vous pouvez acheter dans les quin-

cailleries.

L’expédition des marchandises se fera sans délai, excepté en cas de grèves, de feux ou toutes autres circonstances indépendantes de notre 

volonté.

  Empire Comfort Systems, Inc. 

Belleville, Illinois

lIste des PIèces

Façon de coMMander les PIèces de réParatIon

22

R-3031

Brûleur (exige 6)

23

P-88-55

orifice du brûleur - NAT (exige 6)

23

P-88-65

orifice du brûleur - PL (exige 6)

24

GWT-014

Volet avant pour l’air -PL(exige 2)

25

GWT-015

Volet arrière pour l’air -PL(exige 2)

26

GWT-054

Volet du bas pour l’air - PL  

(exige 2)

27

23906

Protection

28

36354

Enveloppe complète (comprend n°7, 

n°9 et deux n°10)

29

24752

Blindage inférior

30

29011

Support de tube d’échangeur

Pas  

Représenté

GWT-099

Tubulure de la veilleuse

Pas 

Représenté

R-3178

orifice de la veilleuse  (Honeywell K14 

.014 PL seulement)

Pas 

Représenté

R-3179

orifice de la veilleuse  (Honeywell  A26 

.026 NAT seulement)

Pas 

Représenté

R-734

Porte-allumette

Pas 

Représenté

GWT-190

Ensemble de quincaillerie

Numéro 

d’index 

Numéro 

de la pièce 

Description

Summary of Contents for GWT-50W

Page 1: ...r other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phon...

Page 2: ...Ventilation and Combustion Air 8 Location All Models 8 Rough In Instructions 8 9 Finishing Instructions 9 10 Optional On Off Device 11 Lighting Instructions 12 Vent Safety Shutoff System 13 Proper Ma...

Page 3: ...inspectedbeforeuseandatleast annually by a qualified service person More frequent cleaning may be required due to excessive lint from carpeting bedding materials etc It is imperative that control comp...

Page 4: ...hts perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on...

Page 5: ...57mm above the floor Such equipment shall be located or protected so it is not subject to physical damage by a moving vehicle Qualified Installing Agency Installation and replacement of gas piping gas...

Page 6: ...as well as condensation of flue products an insulated vent enclosure is recommended Use Type B vent pipe and maintain at least a one inch 25mm clearance to combustibles Use metal thimble to protect ve...

Page 7: ...at a drip line be installed near the gas inlet This should consist of a vertical length of pipe tee connected into the gas line that is capped on the bottom in which condensation and foreign particles...

Page 8: ...ts Do not install in a closet alcove or small hallway where the furnace could be isolated by closing doors to the heated space When location is selected check the walls attic and roof to make sure the...

Page 9: ...finish materials to project into furnace recess 66 1 8 1679 mm WALL OPENING 14 368 mm Figure 4 Installing Furnace Figure 5 Cleartherecessofalldebris andremoveanywoodplaster grounds Stand the furnace...

Page 10: ...o header with one 1 8 x 3 8 Phillips screw when optional blower is not installed Attention Use outside clearance holes on outer casing top for attachment to header with two 2 8 x 3 8 Phillips screws w...

Page 11: ...the ON OFF device 4 to 5 feet above the floor on an interior wall not affected by another heating source i e stove or water heater or the temperature of an adjoining room Proper operation depends on a...

Page 12: ...emove control access panel control door 3 Push in gas control knob slightly and turn clockwise to OFF Do not force 4 Replace control access panel control door 1 Stop Read the safety information above...

Page 13: ...ner flame with a much larger light blue outer flame The burner does not have a primary air adjustment The flame will be proper if the factory set pressure and orifice are used After the furnace has be...

Page 14: ...with a match If Pilot Does Not Light By Any Means 1 Check gas control knob for being in the Pilot position 2 Check pilot adjustment for being full open counterclockwise to open 3 If gas is available i...

Page 15: ...rectly to the service person dealer All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number from the name plate on your equipment Then determine the Par...

Page 16: ...37410 0 0616 Page 16 PARTS VIEW 7 5 6 4 8 9 10 13 16 22 23 24 25 26 20 22 23 26 25 24 21 19 18 9 27 10 11 12 13 17 8 15 14 6 5 7 4 3 2 1 28 12 29 30 30...

Page 17: ...ll 12 Attach caps and plugs from blower housing and blower front 13 Attach blower front to blower housing with 4 8 x 3 8 screws from Step 6 14 Installation of optional blower assembly is completed Cau...

Page 18: ...m this plug For an ungrounded receptacle an adapter which has two prongs and a wire for grounding can be purchased plugged into the ungrounded receptacleanditswireconnectedtothereceptaclemountingscrew...

Page 19: ...ance must be installed by a qualified installer and operated in accordance with the instructions furnished with the appliance A bill of sale cancelled check or payment record should be kept to verify...

Page 20: ...mpire Comfort Systems Inc Belleville IL If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question please contact your dealer...

Page 21: ...u liquides inflammables dans le voisnage de cet appareil ou de tout autre appareil QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareil Ne touchez a aucun interrupteur Ne pas v...

Page 22: ...ons Sommaires 8 9 Instructions pour la Finition 9 10 Installation d un dispositif de marche arr t Mod les SG 11 Instructions d Allumage 12 Le Syst me de Fermeture de S ret de l vent 13 Aspect Convenab...

Page 23: ...ents nettoyages seront requis Il est imp ratif que les compartiments de commandes les br leurs et les passages de circulation d air de l appareil soient gard s propres Ne rien mettre autour de la four...

Page 24: ...ces endroits avant d y aller Utiliser le t l phone de votre voisin et appeler les pompiers et une personne entra n e avec le propane Ne pas ouvrir les soupapes d approvisionnement de gaz m me si vous...

Page 25: ...ns les garages r sidentiels employant du gaz doivent tre install s de fa on ce que les br leurs et les appareils pour allumer les br leurs doivent tre situ s au moins 45 7cm au dessus du plancher Tous...

Page 26: ...acuation nousrecommandonsd isoler l enceinte d vent Utiliser les tuyaux d vacuation de type B et garder un espace libre d au moins 1 2 54cm aux combustibles Utiliser une bague en m tal pour prot ger l...

Page 27: ...autorit s ayant juridiction L tat de Massachusetts exige qu une connexion flex ible d un appareil n exc de pas une longueur de trois pieds Test de Pression du Syst me d Alimentation de Gaz 1 Pour v r...

Page 28: ...er les murs le grenier et le toit pour tre certain qu il n y a pas d obstruction telles que des tuyaux desfils lectriques etc lesquelsentraveraientl installation de la fournaise ou le tuyau d vacuatio...

Page 29: ...LLECTRICE MONTANTS 2 x4 51mm x 102 mm LAMBOURDE 2 x4 51mm x 102mm 66 1 8 1679 mm OUVERTURE MURALE Basculer la fournaise et ins rer le tuyau d vacuation dans l ouverture rectangu laire dans la plaque c...

Page 30: ...ibres ext rieurs de la partie su p rieure de la paroi ext rieure pour attacher le collecteur avec deux 2 vis Phillips 8 x 3 8 lorsque la soufflerie facultative est install e 3 Aligner les trous libres...

Page 31: ...l absence d instructions installez le dispositif de marche arr t 1 2 1 5 m tres 4 5 pieds au dessus du sol sur un mur int rieur qui ne subit pas l effet d une autre source de chaleur po le ou chauffe...

Page 32: ...er le panneau d acc s aux commandes porte des commandes 11 Allumertoutlepouvoir lectriquedel appareil siapplicable 1 Si l entretien doit tre fait teindre tout le pouvoir lectrique l appareil si applic...

Page 33: ...t rieure avec une flamme ext rieure bleue p le beaucoup plus grande Il n y a pas d ajustement d air primaire pour le br leur La flamme sera ad quate si la pression pr ajust e l usine et les orifices s...

Page 34: ...bouton de contr le de gaz il doit tre dans la position Veilleuse 2 V rifier l ajustement de la veilleuse il doit tre compl tement ouvert dans le sens oppos des aiguilles d une montre pour ouvert 3 S i...

Page 35: ...entretien ou au vendeur Toutes les pi ces num r es dans la liste ont un num ro de pi ce Lorsque vous commandez des pi ces premi rement obtenez le num ro du mod le sur la plaque d identification de l a...

Page 36: ...37410 0 0616 Page 16 VUE DES PI CES 7 5 6 4 8 9 10 13 16 22 23 24 25 26 20 22 23 26 25 24 21 19 18 9 27 10 11 12 13 17 8 15 14 6 5 7 4 3 2 1 28 12 29 30 30...

Page 37: ...lerie facultative est compl t e Attention Lorsque vous installez le ch ssis de la soufflerie sur le mur faites attention de ne pas endommager le serpentin du moteur Installation de la soufflerie avec...

Page 38: ...t tre attach la vis du support de la prise de courant Avec ce fil compl tant la mise terre la fiche de l appareil peut tre branch e dans l adaptateur AVERTISSEMENT D brancher l accessoire de la souffl...

Page 39: ...37410 0 0616 Page 19 Notes de Service...

Page 40: ...RE Comfort Systems Empire Comfort Systems Inc Belleville IL Pour toute question g n rale concernant nos produits veuillez nous envoyer un courriel info empirecomfort com Pour toute question d entretie...

Reviews: