background image

27136-0-0110

Page 4

Sidewall clearances:

 The clearance from the inside of the firebox 

to perpendicular combustible side wall should not be less than 

6". 

See figure 1.

Firebox Side and Back Clearances:

 The firebox outer casing side 

and back flanges are zero clearance to combustibles.

Top framing and finishing:

 combustible framing may rest on 

top of standoffs. Combustible finishing materials may extend 

to the top standoff screws on the front edge of the outer wrap. 

See figure 2

.

ceiling clearances:

 The ceiling height should not be less than 42" 

from the top of the hood. 

See Figures 3a and 3b.

Mantel clearances: 

Vent free firebox models must use the hood 

supplied  with  the  firebox,  or  one  of  the  optional  hood  kits 

available for each model. if a combustible mantel is installed, 

it must meet the clearance requirements detailed below.

grate clearance: 

The minimum clearance between the front legs 

of the grate and front edge of the firebox is 2".

Leave at least 36" clearance from the front of the firebox.

cLeaRanceS

45°

6”

3”

MAX.

PERPENDICULAR
SIDE WALL

FRONT FACE (SIDE)

FIREBOX

(TOP VIEW)

COMBUSTIBLE
MATERIALS ALLOWED
IN SHADED AREAS

FIREBOX

STAND OFF

FINISH WITH TRIM KIT OR

NON-COMBUSTIBLE MATERIAL

AS DESIRED.

COMBUSTIBLE

FINISHED WALL

OR MANTEL

2 X 4

HEADER

MANTEL

STANDARD
HOOD

13”

10”

12”

MAX

42”

MIN.

(CEILING TO
TOP OF HOOD)

11 1/2”

MIN.

FIREBOX
FACE

84”

MIN.

(CEILING TO FLOOR)

CEILING

COMBUSTIBLES

ALLOWED

3/8” COMBUSTIBLE
CLEARANCE REQUIRED
FROM TOP EDGE
OF FIREBOX

10”

22”

8”

20”

6 ½”

18”

5”

16”

3 ½”

14”

2”

12 ½”

3/4”

24 ½”

0”

figure 1

figure 2

figure 3a - Mantel clearances with Standard hood

Figure 3b - Mantel Clearances with Optional Extended Hood

MANTEL

EXTENDED HOOD
(VB4H SERIES)

10”

12”

MAX

42”

MIN.

(CEILING TO
TOP OF HOOD)

8”

MIN.

FIREBOX
FACE

84”

MIN.

(CEILING TO FLOOR)

CEILING

COMBUSTIBLES

ALLOWED

3/8” COMBUSTIBLE
CLEARANCE REQUIRED
FROM TOP EDGE
OF FIREBOX

10”

22”

8”

20”

6 ½”

18”

5”

16”

3 ½”

14 ½”

2 ½”

24 ½”

0”

16 ½”

Summary of Contents for VFP36FB0F-3

Page 1: ...instructions supplied with the decora tive type unvented room heater for the minimum fireplace size requirement DO NOT INSTALL a vent free log set IN THIS FIREBOX UNLESS THIS FIREBOX MEETS THE MINIMUM...

Page 2: ...Gas Line Connection 8 Optional Fresh Air Kit Installation Instructions 9 11 Optional Single Speed Blower Installations Instructions 12 14 Junction Box Wiring Installation Instructions 15 Maintenance...

Page 3: ...such component part or accessory Any such action may create a possible fire hazard Consult your local building codes Firebox Screen The firebox screen must be in place when the firebox is operating I...

Page 4: ...Grate Clearance The minimum clearance between the front legs of the grate and front edge of the firebox is 2 Leave at least 36 clearance from the front of the firebox CLEARANCES 45 6 3 MAX PERPENDICUL...

Page 5: ...g tile or other combustible material other than wood flooring it should be installed on a metal or wood panel extending the full width and depth of the unit At this point you should have decided what...

Page 6: ...6 Figure 6 Firebox Dimensions J K H I A G F B E C D L M FIREBOX INSTALLATION INSTRUCTIONS continued VFP36 A 41 1 8 B 39 1 2 C 21 7 16 D 32 1 4 E 38 1 2 F 36 G 27 13 16 H 6 1 8 I 34 J 8 3 8 K 5 5 8 L...

Page 7: ...installed before the firebox is used Failure to do so may create a possible fire hazard The hood is located inside the firebox If brass stainless steel or hammered pewter hoods are desired they can be...

Page 8: ...for all LP fireboxes to reduce the supply tank pressure to a maximum of 14 w c This is in addition to the regulator fitted to the log set WARNING CONNECTION DIRECTLY TO AN UNREGULATED L P TANK CAN CAU...

Page 9: ...uce outside air to the fireplace or firebox as desired It must be installed prior to or at the time of fireplace or firebox installation to framing The FreshAir kit must be installed prior to the inst...

Page 10: ...LY OUTER CASING FRESH AIR ROD OUTSIDE AIR ROD BRACKET Figure 18 OUTSIDE AIR ROD BRACKET OPEN FRESH AIR ROD CONTROL LEVER LEFT SIDE VIEW OF FIREBOX OPENING TOP CUTAWAY VIEW DAMPER ASSEMBLY OUTER CASING...

Page 11: ...clamps or screws 3 Run the other end of the duct through the exterior wall cut out 4 From the outside of the building connect the duct to the collar on the outside air vent assembly with band clamp or...

Page 12: ...activate pow er to the Firebox and control the operation of the FBB5 Blower assembly It is recommended that installation of the wiring be performed by a qualified electrician See Figure 23 1 If instal...

Page 13: ...minal Attach this terminal to the open terminal on the blower power cord See Figure 29 Connection B 10 Route the wires away from moving parts of the blower as sembly and retain wires together near the...

Page 14: ...a dirty blower wheel Remove fan and clean blower wheels Warning Unplugging of blower accessory will not stop the heater from cycling To turn off gas to the heater millivolt model push in gas control k...

Page 15: ...box Install a ULlisted cable clamp not supplied in the knockout hole Leave approximately 6 of wire in the junction box for connection Attach black wire to one side of the receptacle and white wire to...

Page 16: ...PART NO DESCRIPTION 1 17247 TOP STANDOFF 2 10554 FRAMING BRACKET 3 17162 JUNCTION BOX ASSEMBLY 4 R3492 RECEPTACLE 5 R3491 COVER JUNCTION BOX 6 20145 HOOD 7 R7052 ROD SCREEN 8 R8201 SCREEN CURTAIN 9 R8...

Page 17: ...27136 0 0110 Page 17 PARTS VIEW 2 3 4 5 6 7 8 1 10 9 2 2 2...

Page 18: ...Variable Speed Control Kit Wall mounted variable speed control for use with FBB5 blower SCV 1 Fresh Air Kit 1 2 8 4 7 6 5 3 Deluxe and Premium Fireboxes BVA 1 Frame Kits Extruded Aluminum Frame Kits B...

Page 19: ...ered Pew ter and Stainless Steel finishes Contact dealer for all available optional hood accessories Decorative Door Kits Available as optional kits in Black Brass Hammered Pew ter and Stainless Steel...

Page 20: ...eater Hearth and Grills Victor Division of F W Webb Company 200 Locust Street Hartford CT 06114 Phone 860 722 2433 Toll Free 800 243 9360 Fax 860 293 0479 Toll Free Fax 800 274 2004 Websites www fwweb...

Page 21: ...27136 0 0110 Page 21 SERVICE NOTES...

Page 22: ...27136 0 0110 Page 22 SERVICE NOTES...

Page 23: ...27136 0 0110 Page 23 SERVICE NOTES...

Page 24: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Reviews: