TO TURN OFF GAS TO FIREPLACE

1.  STOP! Read the safety information above.

2.  Turn OFF electric power to the appliance.

3.  Turn gas shut-off valve counterclockwise 

 to 

 

On position.

4.  Wait ten (10) minutes to clear out any gas. Then smell for 

gas, including near the floor. If you smell gas, STOP! Follow 

B in the safety information above on this page. If you do not 

smell gas, go to the next step.

5.  Turn ON electric power to the appliance.

6.  Find pilot. The pilot is next to the burner.

7.  Turn main flame to on. If the pilot does not light within 60 

seconds, stop and go to Step 5.

8.  Refer to remote control instructions for detailed information, 

control features, and operation. 

Notice:

 There is a CPI/

IPI switch for a continuous standing pilot mode or an 

intermittent pilot mode. See appliance manual for location 

of this switch. If the pilot or burner does not stay lit (in the 

standing pilot mode), stop and immediately call a qualified 

service technician or gas supplier.

9.  If the burner or pilot does not operate properly after several 

tries, turn the gas valve clockwise 

 to OFF and call 

your service technician or gas supplier.

10.  Operation of the gas valve is controlled by a manual on/

off switch or a hand held remote control. Refer to remote 

instructions for detailed operation information.

FOR YOUR SAFETY REAd BEFORE LIGHTING

A.  

This appliance has a pilot which can be lit by hand or by 

switching the remote receiver switch to the "ON" position. 

When lighting the pilot, follow these instructions exactly.

B.  Before lighting smell all around the appliance area for gas. 

Be sure to smell next to the floor because some gas is 

heavier than air and will settle on the floor.

  What To Do If You Smell Gas

•  Do not try to light any appliance.

•  Do not touch any electrical switch; 

•  Do not use any phone in your building.

•  Immediately call your gas supplier from a neighbor's 

phone. Follow the gas supplier's instructions.

•  If you cannot reach your gas supplier, call the fire 

department.

C.  If applicable, use only your hand to turn the gas shutoff valve 

handle. Never use tools. If the handle will not turn by hand, 

don't try to repair it; call a qualified service technician. Force 

or attempted repair may result in a fire or explosion.

D.  Do not use this appliance if any part has been under water. 

Immediately call a qualified service technician to inspect the 

appliance and to replace any part of the control system and 

any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.   Set REMOTE/OFF/ON switch to OFF.

2.   Turn off all electric power to the appliance if service is to be 

performed (if applicable).

3.   Turn gas shut-off clockwise 

 to OFF. Do not force.

LIGHTING INSTRUCTIONS

GAS SHUT-OFF VALVE

WARNING

If you do not follow these instructions exactly, a fire or explosion may result causing property damage, 

personal injury or loss of life.

Summary of Contents for VFLB60FP90N

Page 1: ... distribution network in this industry These fireplace models combine our proven technologies with exceptional artistry and craftsmanshiptoaddbeautyandwarmthtoanyhome There are several decorative options available for the fireplace Contact your Empire dealer for more information CONTEMPORARY LINEAR VENT FREE GAS FIREPLACE ModELS VFLB 60 72 Fp90 n p 1 HOMEOWNER S MANUAL ...

Page 2: ...e can cause serious injury or death from fire burns explosions or carbon monoxide poisoning Television Considerations Installing a television above a fireplace has become increasingly popular however the area above any fireplace gets hot and most TV manufacturers recommend against placing their products near a heat source If a television is installed above the fireplace Empire Comfort Systems acce...

Page 3: ...o lock in place See Figure 3 Figure 3 REMOVING AND REPLACE THE BARRIER SCREEN ASSEMBLY HOMEOWNER REFERENCE INFORMATION We recommend that you record the following information about your fireplace Model Number ______________________________ Date purchased _________________________ Serial Number ______________________________ Location of fireplace ______________________ Dealer Name __________________...

Page 4: ...s or glass Use decorative logs rocks and glass only from Empire Comfort Systems and specifically for the VFLB60FP or VFLB72FP Keep the decorative media on the wire mesh support Do not restrict air flow 1 Apply the crushed glass to the shaded area only See Figure 4 Use enough to cover the floor of the fireplace but do not allow the media to reach higher than the flange surrounding the burner Never ...

Page 5: ...AD BEFORE LIGHTING A This appliance has a pilot which can be lit by hand or by switching the remote receiver switch to the ON position When lighting the pilot follow these instructions exactly B Before lighting smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor What To Do If You Smell Gas Do not try to li...

Page 6: ...e Figure 6 The Transmitter is powered by 3 AAA type batteries A Mode Button is provided to Index between the features and a Thermostat Button is used to turn on off or index through thermostat functions See Figures 6 and 7 Blue LCD Display UP DOWN Arrow Button ON OFF Button THERMOSTAT Button MODE Button Figure 6 Proflame Transmitter Remote Control Figure 7 Transmitter LCD display LED Brightness Bu...

Page 7: ...sets to the particular code of that transmitter The system is now initialized Temperature Indication Display With the system OFF press the Thermostat Button and the Mode Button at the same time Verify that a C or F is visible to the right of the Room Temperature display See Figures 8 and 9 Figure 8 Fahrenheit Figure 9 Celsius USING THE REMOTE CONTROL Cont d Turn On the Fireplace Press the ON OFF B...

Page 8: ...one step until the flame is turned off Pushing the up arrow button will increase the flame height each time it is pressed Pushing the up arrow button while the system is on but the flame is off will light the burner the flame will come on in the high position See Figures 11 and 12 A single beep confirms receipt of the command Figure 11 Figure 12 Figure 13 Figure 14 USING THE REMOTE CONTROL Cont d ...

Page 9: ...the Transmitter SET TEMPERATURE ROOM TEMPERATURE Figure 15 Figure 16 USING THE REMOTE CONTROL Cont d Smart Thermostat Transmitter Operation The Smart Thermostat function adjusts the flame height in accordance to the difference between the set point temperature and the actual room temperatures As the room temperature gets closer to the set point the Smart Function will modulate the flame down To ac...

Page 10: ...ppear See page 11 to change batteries in remote switch Figure 20 USING THE REMOTE CONTROL Cont d Receiver When the receiver batteries are low no beep will be emitted when it receives an ON OFF command from the transmitter Replace the batteries Manual Bypass of the Remote System If the batteries of the receiver or transmitter die you can still operate the fireplace manually by sliding the three pos...

Page 11: ...e AND Cleaning Oxygen Depletion Sensor Pilot When the pilot has a large yellow tip flame clean the Oxygen Depletion Sensor as follows 1 Use canned air to blow through hole A See Figure 22 This will blow out foreign materials such as dust lint and spider webs C B A Intermittent Pilot Figure 22 WARNING Never use needles wires or similar cylindrical objects to clean the pilot to avoid damaging the ca...

Page 12: ... from the date of purchase Empire will repair or replace at Empire s option WARRANTY Duties Of The Owner The appliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the appliance A bill of sale cancelled check or payment record should be kept to verify purchase date and establish warranty period Ready access to the appliance for service ...