background image

Page 19

20248-2-0806

  Empire Comfort Systems, Inc.   Nine Eighteen Freeburg Ave.    Belleville, Illinois  62220-2623     

 USE ONLY MANUFACTURER'S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH.

 

Index 

   Part

  No. 

Number 

Description

 

Index 

   Part

  No. 

Number 

Description

  1 

20217 

TRIM - TOP

  2 

20215 

TRIM - LEFT

  3 

20216 

TRIM - RIGHT

  4 

10554 

NAILING FLANGE (3 REQUIRED)

  5 

11289 

OUTER WRAPPER TOP

  6 

10574 

CORNER BRACE 2

  7 

10573 

CORNER BRACE 1

  8 

11295 

OUTER WRAPPER

  9 

11289 

OUTER WRAPPER BOTTOM

  10 

11460 

LOUVER ASSEMBLY - UPPER

  11 

11462 

SCREEN ASSEMBLY

  12 

11461 

LOUVER ASSEMBLY - LOWER

  13 

11322 

LOUVER HINGE BRACKET (2 RE-

QUIRED)

  14 

11296 

FIREBOX TOP

  15 

11303 

INNER FIREBOX TOP

  16 

11334 

REAR LOG SUPPORT WELDED AS-

SEMBLY

  17 

11302 

FIREBOX WALLS

  18 

11304 

FIREBOX BOTTOM

  20 

P-253 

ORIFICE FITTING - ANGLED

  21 

P-182 

ORIFICE - LPG (20,000 BTU)

  22 

R-5675 

AIR SHUTTER - LPG

  22 

R-5676 

AIR SHUTTER - NAT

  23 

12348 

BURNER ASSEMBLY - LPG

  23 

12347 

BURNER ASSEMBLY - NAT

  24 

11305 

VALVE / REGULATOR BRACKET

NOT SHOWN 

R-5668 

IGNITOR WIRE

NOT SHOWN 

R-4459 

MAGNET (2 REQUIRED)

NOT SHOWN 

12389 

CERAMIC MEDIA (REPAIR)

NOT SHOWN 

15998 

ROCK WOOL

NOT SHOWN 

P-251  

COUPLING - NAT

VF24FP3-1 ONLY

  19 

R-3623 

PILOT ASSEMBLY - LPG

  19 

R-3624 

PILOT ASSEMBLY - NAT

  21 

P-181 

ORIFICE - NAT (20,000 BTU)

  29 

R-5700 

VALVE - NAT

  29 

R-5701 

VALVE - LPG

  30 

11306 

VALVE BRACKET (2 REQUIRED)

  31 

11307 

VALVE COVER PLATE

  32 

R-3436 

REMOTE/OFF/ON SWITCH

NOT SHOWN 

11458 

TUBING (VALVE TO PILOT) - LPG

NOT SHOWN 

11459 

TUBING (VALVE TO BURNER)

NOT SHOWN 

R-4579D  SWITCH WIRE HARNESS

NOT SHOWN 

P-263 

NIPPLE 8"

NOT SHOWN 

15465 

TUBING (VALVE TO PILOT 

REGULATOR) - NAT

NOT SHOWN 

15466 

TUBING (PILOT REGULATOR) TO 

PILOT) - NAT

NOT SHOWN 

R-7063 

PILOT REGULATOR - NAT

VF24FP2-1 ONLY

  19 

R-5170 

PILOT ASSEMBLY - LPG

  19 

R-5171 

PILOT ASSEMBLY - NAT

  21 

P-265 

ORIFICE - NAT (20,000 BTU)

  21 

P-266 

ORIFICE - NAT (10,000 BTU)

  21 

P-193 

ORIFICE - LPG (10,000 BTU)

  29 

16921  

VALVE - NAT

  29 

16922 

VALVE - LPG

  26 

R-2480 

INLET REGULATOR - LPG

  26 

R-2479 

INLET REGULATOR - NAT

  27 

16301 

VALVE COVER PLATE

  28 

R-2313 

PIEZO IGNITOR

NOT SHOWN 

11465 

TUBING (VALVE TO PILOT)

NOT SHOWN 

11466 

TUBING (VALVE TO BURNER)

NOT SHOWN 

16302 

TUBING (REGULATOR TO VALVE)

NOT SHOWN 

P-264  

NIPPLE 5"

NOT SHOWN 

R-1720 

PLASTIC CLIP

ATTENTION: 

 When ordering parts, it is very important that 

part number

 and 

description

 of part coincide.

Parts can be ordered 

only

 through your 

service person or dealer.

  For best results, the service person or dealer should order parts through the  distribu-

tor.  Parts can be shipped directly to the

 service person/dealer.

All parts listed in the Parts List have a Part Number.  When ordering parts, first obtain the Model Number from the name plate on your equipment.  

Then determine the Part Number (

not

 the Index Number) and the Description of each part from the following appropriate illustration and list.  Be sure 

to give all this information.
Fireplace Model Number   

    Part Description 

Fireplace Serial Number 

 

Part Number 

Type of Gas (Propane or Natural) 
Do not order bolts, screws, washers or nuts.  They are standard hardware items and can be purchased at any local hardware store.  
Shipments contingent upon strikes, fires and all causes beyond our control.

PARTS LIST

HOW TO ORDER REPAIR PARTS

Summary of Contents for VF24FP2-1

Page 1: ...s of gas input per hour Refer to page 6 WARNING If not installed operated and main tained in accordance with the manufacturer s in structions this product could expose you to sub stances in fuel or fr...

Page 2: ...Placement 12 Placement of Glowing Embers Rock Wool 12 Operation Instructions Flame Appearance 12 VF24FP3 1 Lighting Instructions 13 VF24FP2 1 Lighting Instructions 14 Pilot Flame Characteristics 15 16...

Page 3: ...azard of high surface temperature and should stay away to avoid burns or clothing ignition Young childrenshould becarefullysupervisedwhen they are in the same room with the appliance Do not place clot...

Page 4: ...ight pilot lights perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or...

Page 5: ...your gas company before changing spud ori ce size WARNING Failure to keep the primary air opening s of the burner s clean may result in sooting and property damage Instructions to Installer 1 Installe...

Page 6: ...s water vapor retarder with a rating of one perm or less with openings gasketed or sealed and b Weatherstripping has been added on openable windows and doors and c Caulking or sealants are applied to...

Page 7: ...ount of BTU Hr used BTU Hr maximum the space can support BTU Hr actual amount of BTU Hr used Example 25 600 BTU Hr maximum the space can support 38 000 BTU Hr actual amount of BTU Hr used Warning If t...

Page 8: ...nectors of Other Than All Metal Construction The above connectors may be used if acceptable by the authority having jurisdiction The state of Massachusetts requires that a exible appliance connector c...

Page 9: ...place opening to any combustible wall or material should not be less than 4 inches 2 Clearances from the top of the replace opening to the ceiling should not be less than 30 inches Mantel Clearances f...

Page 10: ...g ange will secure the replace 6 Placeleftmantelsideagainstbase Insertdowelsinbreastboard into left mantel side 7 Use four 4 pre drilled screw holes on back of breastboard to secure breastboard to man...

Page 11: ...the appliance the gas supply will enter on right hand side See Gas Supply Page 8 3 Insert replace into enclosure 4 Attach nailing anges to framing with a screw or nail 5 Finishedwallsurfacewillbe ush...

Page 12: ...ttle is necessary to cover this area Excess ember material causes the yellow ame to become orange and stringy Apply just enough to obtain slow glow and a gold yellow ame Avoid any drafts that alter bu...

Page 13: ...Turn ON OFF switch to OFF position and or set thermostat if present to lowest setting If applicable Turn off all electric power to the heater 1 STOP Read the safety information label 2 Make sure the m...

Page 14: ...FF GAS TO APPLIANCE 1 Set thermostat gas control knob to lowest setting 2 Turn off all electric power to appliance if service is to be performed if applicable LIGHTING INSTRUCTIONS 7 Turn gas control...

Page 15: ...re 15 If pilot ame pattern is incorrect as shown in Figure 14 See Troubleshooting page 18 Cleaning and Maintenance Pilot Oxygen Depletion Sensor Pilot When the pilot has a large yellow tip ame clean t...

Page 16: ...8 Remove air shutter from ori ce tting 9 ForNaturalgasonly remove20 000BTUmainburnerori ce marked 49 from ori ce tting and replace with 10 000 BTU VF24FP3 1 Main Burner Operation The gas control modul...

Page 17: ...be checked with a millivolt meter 0 1000 MV range Remote Receiver Use the following steps to place the remote receiver adjacent to the gas valve Attention The remote receiver bracket is not used in t...

Page 18: ...rrect Replace gas regula tor 7 ODS pilot lights but ame goes out when control knob is released a Control knob not fully pressed in Press in control knob fully b Control knob not pressed in long enough...

Page 19: ...ITCH WIRE HARNESS NOT SHOWN P 263 NIPPLE 8 NOT SHOWN 15465 TUBING VALVE TO PILOT REGULATOR NAT NOT SHOWN 15466 TUBING PILOT REGULATOR TO PILOT NAT NOT SHOWN R 7063 PILOT REGULATOR NAT VF24FP2 1 ONLY 1...

Page 20: ...Page 20 20248 2 0806 PARTS VIEW 10 27 26 25 VF24FP2 28 VF24FP3 31 29 32 30 1 7 2 4 5 6 8 9 10 11 12 13 25 26 27 28 29 30 31 32 24 3 14 15 16 17 18 19 23 20 21 22...

Page 21: ...box 5 Place the 2 liner mounting brackets over the front edges of the 2 side brick liners Attach liner mounting brackets to outer casing with 4 four 10 x 1 2 screws from Step 4 6 Replacelogsintoburner...

Page 22: ...motor Align and attach blower assembly to outer casing side See Figure 2 10 Snap Heyco into blower shield side 11 Placeblowershieldsideadjacenttomotor Routeblowermotor wires through Heyco on blower s...

Page 23: ...d on left front of valve cover on burner assembly Insert blower shield front adjacent to blower motor and blower shield side Align clearance hole on blower shield front with left front screw hole on v...

Page 24: ...screws at interior top of inner casing that were loosened in Step 6 30 Attach burner assembly to inner bottom with three 3 10 x 1 2 screws from Step 5 31 Attach rear log support to inner casing with t...

Page 25: ...the ground the appliance cord plug can be plugged into the adapter and be electrically grounded CAUTION Labelallwirespriortodisconnectionwhenservic ing controls Wiring errors can cause improper and d...

Page 26: ...part number and description coincide 1 2 3 Index Number Part Number Description VPF24BR Brass Trim Kit 1 11328 Trim Top 2 11326 Trim Left 3 11327 Trim Right VPF24SS Stainless Steel Trim Kit 1 20227 Tr...

Page 27: ...Page 27 20248 2 0806 SERVICE NOTES...

Page 28: ...Page 28 20248 2 0806 Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 PH 618 233 7420 or 800 851 3153 FAX 618 233 7097 or 800 443 8648 info empirecomfort com www empirecomfort com...

Reviews: