background image

Page 14

20248-2-0806

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING:  If you do not follow these instructions exactly, a fire or explosion may result 

causing property damage, personal injury or loss of life.

A.   This  appliance  has  a  pilot  which  must  be  lighted  by 

hand.  When lighting the pilot, follow these instructions 

exactly.

B.   BEFORE LIGHTING  smell all around the appliance 

area for gas.  Be sure to smell next to the floor because 

some gas is heavier than air and will settle on the floor.

 

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electrical switch; 

  Do not use any phone in your building.

• Immediately call your gas supplier from a neighbor's 

phone.  Follow the gas supplier's instructions.

• If you cannot reach your gas supplier, call the fire 

department.

C.   Use only your hand to push in or turn the gas control 

knob.  Never use tools.  If the knob will not push in or 

turn by hand, don't try to repair it; call  a  qualified 

service technician.  Force or attempted repair may 

result in a fire or explosion.

D.   Do not use this appliance if any part has been under 

water.  Immediately call a qualified service technician 

to inspect the appliance and to replace any part of the 

control system and any gas control which has been 

under water.

3.   Push in gas control knob slightly and turn clockwise 

  to "OFF".  Do not force.

TO TURN OFF GAS TO APPLIANCE

1.   Set thermostat (gas control knob) to lowest setting.

2.   Turn off all electric power to appliance if service is to be 

performed (if applicable).

LIGHTING INSTRUCTIONS

  7.   Turn  gas  control  knob  counterclockwise   

  to 

"PILOT."

  8.   Push in gas control knob all the way and hold in.  Repeat-

edly push the piezo ignitor button until pilot is lit (or use 

a match to light pilot).  Continue to hold the control knob 

in for about one (1) minute after the pilot is lit.  Release 

knob and it will pop back up.  Pilot should remain lit.  If 

it goes out, repeat steps 4 through 8.
  •  If  knob  does  not  pop  up  when  released,  stop  and 

immediately call your service technician or gas sup-

plier.  

  •  If the pilot will not stay lit after several tries, turn 

the gas control knob to "OFF" and call your service 

technician or gas supplier.  

  9.  Turn  gas  control  knob  counterclockwise   

  to 

"HI". 

  10.  Turn on all electric power to appliance (if applicable).
  11.  Set thermostat (gas control knob) to desired setting from 

"HI" to "LO".

  1.   STOP!   Read the safety information above.
  2.  Set thermostat (gas control knob) to lowest setting.
  3.  Turn  off  all  electric  power  to  the  appliance    (if  applica-

ble).

  4.   Push in gas control knob slightly and turn clockwise                      

 to "OFF".  Do not force.

 

  5.   Wait ten (10) minutes   to clear out any gas.  Then smell 

for gas, including near the floor.  If you smell gas, STOP! 

Follow "B" in the safety information above.  If you don't 

smell gas, go to the next step.

  6.   Find pilot - the pilot is attached at the bottom of the burner 

assembly .

VF24FP2-1 LIGHTING INSTRUCTIONS

PIEZO IGNITOR

Summary of Contents for VF24FP2-1

Page 1: ...s of gas input per hour Refer to page 6 WARNING If not installed operated and main tained in accordance with the manufacturer s in structions this product could expose you to sub stances in fuel or fr...

Page 2: ...Placement 12 Placement of Glowing Embers Rock Wool 12 Operation Instructions Flame Appearance 12 VF24FP3 1 Lighting Instructions 13 VF24FP2 1 Lighting Instructions 14 Pilot Flame Characteristics 15 16...

Page 3: ...azard of high surface temperature and should stay away to avoid burns or clothing ignition Young childrenshould becarefullysupervisedwhen they are in the same room with the appliance Do not place clot...

Page 4: ...ight pilot lights perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or...

Page 5: ...your gas company before changing spud ori ce size WARNING Failure to keep the primary air opening s of the burner s clean may result in sooting and property damage Instructions to Installer 1 Installe...

Page 6: ...s water vapor retarder with a rating of one perm or less with openings gasketed or sealed and b Weatherstripping has been added on openable windows and doors and c Caulking or sealants are applied to...

Page 7: ...ount of BTU Hr used BTU Hr maximum the space can support BTU Hr actual amount of BTU Hr used Example 25 600 BTU Hr maximum the space can support 38 000 BTU Hr actual amount of BTU Hr used Warning If t...

Page 8: ...nectors of Other Than All Metal Construction The above connectors may be used if acceptable by the authority having jurisdiction The state of Massachusetts requires that a exible appliance connector c...

Page 9: ...place opening to any combustible wall or material should not be less than 4 inches 2 Clearances from the top of the replace opening to the ceiling should not be less than 30 inches Mantel Clearances f...

Page 10: ...g ange will secure the replace 6 Placeleftmantelsideagainstbase Insertdowelsinbreastboard into left mantel side 7 Use four 4 pre drilled screw holes on back of breastboard to secure breastboard to man...

Page 11: ...the appliance the gas supply will enter on right hand side See Gas Supply Page 8 3 Insert replace into enclosure 4 Attach nailing anges to framing with a screw or nail 5 Finishedwallsurfacewillbe ush...

Page 12: ...ttle is necessary to cover this area Excess ember material causes the yellow ame to become orange and stringy Apply just enough to obtain slow glow and a gold yellow ame Avoid any drafts that alter bu...

Page 13: ...Turn ON OFF switch to OFF position and or set thermostat if present to lowest setting If applicable Turn off all electric power to the heater 1 STOP Read the safety information label 2 Make sure the m...

Page 14: ...FF GAS TO APPLIANCE 1 Set thermostat gas control knob to lowest setting 2 Turn off all electric power to appliance if service is to be performed if applicable LIGHTING INSTRUCTIONS 7 Turn gas control...

Page 15: ...re 15 If pilot ame pattern is incorrect as shown in Figure 14 See Troubleshooting page 18 Cleaning and Maintenance Pilot Oxygen Depletion Sensor Pilot When the pilot has a large yellow tip ame clean t...

Page 16: ...8 Remove air shutter from ori ce tting 9 ForNaturalgasonly remove20 000BTUmainburnerori ce marked 49 from ori ce tting and replace with 10 000 BTU VF24FP3 1 Main Burner Operation The gas control modul...

Page 17: ...be checked with a millivolt meter 0 1000 MV range Remote Receiver Use the following steps to place the remote receiver adjacent to the gas valve Attention The remote receiver bracket is not used in t...

Page 18: ...rrect Replace gas regula tor 7 ODS pilot lights but ame goes out when control knob is released a Control knob not fully pressed in Press in control knob fully b Control knob not pressed in long enough...

Page 19: ...ITCH WIRE HARNESS NOT SHOWN P 263 NIPPLE 8 NOT SHOWN 15465 TUBING VALVE TO PILOT REGULATOR NAT NOT SHOWN 15466 TUBING PILOT REGULATOR TO PILOT NAT NOT SHOWN R 7063 PILOT REGULATOR NAT VF24FP2 1 ONLY 1...

Page 20: ...Page 20 20248 2 0806 PARTS VIEW 10 27 26 25 VF24FP2 28 VF24FP3 31 29 32 30 1 7 2 4 5 6 8 9 10 11 12 13 25 26 27 28 29 30 31 32 24 3 14 15 16 17 18 19 23 20 21 22...

Page 21: ...box 5 Place the 2 liner mounting brackets over the front edges of the 2 side brick liners Attach liner mounting brackets to outer casing with 4 four 10 x 1 2 screws from Step 4 6 Replacelogsintoburner...

Page 22: ...motor Align and attach blower assembly to outer casing side See Figure 2 10 Snap Heyco into blower shield side 11 Placeblowershieldsideadjacenttomotor Routeblowermotor wires through Heyco on blower s...

Page 23: ...d on left front of valve cover on burner assembly Insert blower shield front adjacent to blower motor and blower shield side Align clearance hole on blower shield front with left front screw hole on v...

Page 24: ...screws at interior top of inner casing that were loosened in Step 6 30 Attach burner assembly to inner bottom with three 3 10 x 1 2 screws from Step 5 31 Attach rear log support to inner casing with t...