background image

37854-0-0117

Page 2

Empire Comfort Systems Inc. • Belleville, IL

4.  Run thermostat wire from the wall box opening to a floor or 

wall opening beneath the left side of the wall furnace’s rear 

shroud near the temperature sensor. Ensure enough wire 

extends through the openings to make the connections. It 

may be necessary to remove the wall furnace from the rear 

shroud to create the thermostat wire opening and route the 

thermostat wires.

5.  Remove the wall furnace’s front panel and turn off gas and 

power to the wall furnace. If the wall furnace needs to be 

removed from the rear shroud, disconnect the wall furnace 

from the gas line and venting. Remove the four screws se-

curing the rear shroud then move the wall furnace away from 

the wall. See the venting section of the wall furnace installa-

tion instructions.

6.  Connect two thermostat wires to the wire leads on the con-

nector harness assembly provided with this kit using two wire 

nuts, note wire color. Route the end of the plug through an 

upper slot in the side of the rear shroud. 

See Figure 3.

Figure 3

7.  If the wall furnace has been removed from the rear shroud 

move the wall furnace back into position and re-attach the 

gas line and venting. Re-attach the rear shroud with the 

screws removed in step 5. See the venting section of the 

wall furnace installation instructions.

8.  Remove temperature sensor from wall furnace and 

insert the wire harness connector. 

See Figure 4.

 Retain 

temperature sensor.

Figure 4

9.  At the wall box opening connect the two thermostat wires to 

the two wire leads on the wall bracket assembly. Insert tem-

perature sensor from step 8 into the wall bracket assembly. 

Insert the wall bracket assembly into the wall box opening. 

See Figure 5.

Figure 5

10.  Install the cover plate, the temperature sensor must protrude 

through the hole in the center of the cover plate. The cover 

plate screws will pass through the holes in the wall bracket 

assembly and secure both to the wall box. 

See Figure 6.

Figure 6

NOTE:

  The cover plate may be re-finished prior to installation 

to match the room decor. The hole in the center of the 

plate MUST remain clear for the temperature sensor to 

function properly. 

Caution:

  If re-finishing the cover plate after installation, DO NOT 

paint or cover the temperature sensor.

11.  Turn power and gas to the wall furnace back on.