OPTIONAL CONTROLLERS
See your Mantis dealer for correct controller type.
TEMPERATURE CONTROLLERS
FRBTP
Battery Operated Remote with Programmable Thermostat
FRBTC
Battery Operated Remote with Thermostat
TRW
Battery Operated Wireless Remote Wall Thermostat
TMV2
Thermostat, 2 Stage
T24V
Thermostat, 24 Volt
TDV1
Wall Thermostat, 24 Volt
INSTRUCTIONS MUST BE LEFT WITH THE OWNER FOR FUTURE REFERENCE AFTER INSTALLATION
Installation Instructions for FRBTP, FRBTC, and TRW
Remote Controls FRBTP, FRBTC and TRW are all battery operated devices. Begin installation by unplugging the unit and removing
the front louver panel.
Remove wire nut from black and white wire from junction box.
Black or white wire can be inserted in either remote control receiver connection hole or connected to T24V thermostat screws. There is
no polarity at this connection.
Figure 68
Replace front louver panel and plug unit into outlet. Turn both burner switches to the ON position. Burner switches must remain in the
ON position for remote to function. Set remote from the instructions provided with the remote control. Set T24V thermostat to desired
temperature.
Note:
When the heater will not be used for long periods, the burner switches should be in the OFF position, and the heater should be
turned off at the power point.
Installation Instruction for TMV2 - Two Stage Thermostat Model:
Begin installation by unplugging the unit and removing the front louver panel.
Determine mounting location of thermostat. Using standard 18 AWG wire, run four (4) strands of wire into rear of Mantis
(See Figure 69) to junction block. Cut wire to correct length. Remove blue jumper wire from junction block and save for future use.
Connect four (4) new thermostat wires to Mantis using schematic. See Figure 70.
Figure 69
W1 R
W2
C
REMOTE
CONTROL
RECEIVER OR
T24V THERMOSTAT
BLACK
WHITE
WHITE
JUNCTION
BLOCK
BLUE
RED
BLACK
WHITE
BLUE
TO
TRANSFORMER
TO “T1” (FRONT BURNER)
TO “T2” (REAR BURNER)
TO “T1”
TO “T2”
FLUE OUTLET
AIR INLET
ELECTRIC CORD
GAS LINE
THERMOSTAT WIRE