background image

FG10239-1-0214

Page 8

INSTALLATION

FOR MATCH THROW INSTALLATIONS

1.  Place the Fiamma Burner Pan into the fireplace (unit is pack

-

aged as a match-throw, dual burner assembly; valve,pilot and 

gas train must be assembled). The unit should be centered 

from both side to side and front to back in the fireplace. The 

unit is shipped ready for rear gas connection only. See Figure 

2.

2.  Bend a 3/8” gas line with two 3/8” brass, female flare fittings 

(included on some models) to facilitate the gas connection 

between the burner and the gas stub.

CAUTION: 

Gas lines are easily kinked if bent too sharply.

3.  Using an adjustable wrench, and turning in a clockwise 

direction, attach a 1/2” female flare x 3/8” male flare brass 

reducer fitting (included on some models) to the gas stub.

4.  Using two adjustable wrenches, and turning in a clockwise 

directions, attach one end of the gas line to the brass re-

ducer fitting installed in the previous step (one wrench on the 

brass gas line fitting, and one wrench on the brass reducer 

fitting).

5.  Using two adjustable wrenches, and turning in a clockwise 

direction, attach the other end of the gas line to the brass 

fitting on the burner (one wrench on the gas line fitting, and 

one wrench on the brass fitting on the burner).

CAUTION: 

Make sure all gas connections are snug but DO 

NOT over tighten!

6. 

CHECK FOR LEAKS!

 Apply soapy water to each connection 

and watch for bubbles. If bubbles are seen, turn off the gas 

supply, retighten the connections and 

CHECK AGAIN. DO 

NOT

 use a lighted match or other source of ignition to check 

for leaks. Repeat this procedure until you are sure that there 

are no leaks. Proceed to “FINAL SET UP on page 12.

FOR VALVE/PILOT INSTALLATIONS

It will be easier to assemble the burner/gas train outside of the 

fireplace and then place the entire assembly into the fireplace 

for final gas hook-up. Follow the instructions that are included 

with the valve/pilot kit and/or the instructions below.

Figure 4 - Valve/Pilot Assembly Parts

Figure 5 - Rear View Standard Assembly

STANDARD PAN - VALVE/PILOT ASSEMBLY

1.  Assemble the valve/pilot kit. See Figures 4 to 5.

2.  Noting the distance between the grate tines, place the pilot 

mounting bracket on the right, rear of the burner pan, 2-1/4” 

from the right-hand side of the burner pan and 3/16” down 

from the top edge. See Figure 6.

3.  Mark the location of the pilot bracket mounting hole.

4.  Drill a 1/8” hole at this location. Or secure the bracket with a 

self-tapping sheet metal screw. See Figures 6 and 7.

5.  Mount the pilot. See Figure 8.

6.  Attach the 3/8” stainless steel flex line from the valve to the 

burner. See Figure 8.

Figure 6

Figure 7

Summary of Contents for FIAMMA BX18MTN-1

Page 1: ...to substances in fuel or from fuel combustion which can cause death or serious illness WARNING This appliance must be installed only in a solid fuel burning fireplace with a working flue and construc...

Page 2: ...FICATIONS 6 INSTALLATION 7 11 FINAL SET UP 12 LIGHTING INSTRUCTIONS MATCH THROW UNITS 13 LIGHTING INSTRUCTIONS SAFETY PILOT UNITS 14 OPERATION 15 MAINTENANCE SERVICE 16 TROUBLESHOOTING 17 PARTS LIST 1...

Page 3: ...e and draperies Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition Young children should be carefully supervised...

Page 4: ...nitial operation of the appliance This may possibly cause headaches and eye or lung irritation This is a normal and temporary occurrence The initial break in period should last three to four hours Dur...

Page 5: ...alls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a closed area and the odor intensity could v...

Page 6: ...IMENSIONS MASONRY BUILT FIREPLACES Chimney Height Minimum of 6 Feet LOG SET SIZE FRONT WIDTH IN INCHES DEPTH IN INCHES HEIGHT IN INCHES MINIMUM VENT IN SQ INCHES 18 28 16 18 49 24 30 16 18 71 30 36 18...

Page 7: ...appliance see the specifications beginning on page 6 of this manual IMPORTANT This appliance when first installed may produce unpleasant odors these will gradually diminish IMPORTANT Decorative Gas Lo...

Page 8: ...the brass fitting on the burner CAUTION Make sure all gas connections are snug but DO NOT over tighten 6 CHECK FOR LEAKS Apply soapy water to each connection and watch for bubbles If bubbles are seen...

Page 9: ...at there are no leaks Proceed to FINAL SET UP on page 12 WARNING DO NOT use sand in Liquid Propane Hearth Kits Use the Vermiculite provided with the Liquid Propane Change Kit FOR UNITS WITH REMOTE SYS...

Page 10: ...s on programming the coding switches on both transmitter and receiver Figure 11 Hand Held Remote Receiver Front View Figure 12 Hand Held Remote Receiver Rear View Figure 13 Hand Head Remote Receiver T...

Page 11: ...both transmitter and receiver Figure 14 Wall Mount Variable Flame Remote Receiver Front View Figure 15 Wall Mount Variable Flame Remote Receiver Rear View Figure 16 Wall Mount Variable Flame Remote Re...

Page 12: ...ual DO NOT apply extra material not supplied with this appliance All previously applied loose material em bers must be removed prior to reapplication CAUTION DO NOT place glowing embers sand vermiculi...

Page 13: ...as Match Throw Units can be lit by long hearth match hand fire starter or book match clip extender inserted near the center of the burner system 1 STOP Read the safety information above 2 Read all war...

Page 14: ...ove 2 Read all warnings and safety information in this manual WARNING BE SURE THAT THE CHIMNEY DAMPER IS FULLY OPEN 3 Push in the gas control knob slightly and turn it in a clockwise direction to the...

Page 15: ...place when this appliance is in operation Unless other provisions for combustion air are provided the screen shall have an opening s for introduction of combustion air WARNING When this decorative gas...

Page 16: ...in chimney and or vents and clean if necessary 4 Inspect the pilot and burners if applicable The burner system has been adjusted for proper operation at the factory No adjustment is necessary other t...

Page 17: ...ressure Check gas supply pressure Faulty valve Replace valve Faulty pilot or thermocouple Replace Safety pilot Clogged or dirty burner ports Clean burner ports Burner pilot light but will not stay on...

Page 18: ...FG10086 LAVA ROCK 5 FG10010 FG10010 FG10010 FG10010 DAMPER CLAMP 6 FG10020 FG10020 FG10020 FG10020 ORIFICE MT BRASS ELBOW 375 M X 375 M 50 20 TAP 7 FG10400 FG10292 FG10292 FG10292 ORIFICE 8 FG10065 F...

Page 19: ...FG10239 1 0214 Page 19 PARTS VIEW...

Page 20: ...ranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Numb...

Page 21: ...s option Duties of the Owner The appliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the ap pliance A bill of sale cancelled check or...

Page 22: ...FG10239 1 0214 Page 22 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Page 23: ...FG10239 1 0214 Page 23 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Page 24: ...ms Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Reviews: