IMPORTANT SAFETY INFORMATION

WARNING: Follow all gas leak check procedures in this manual, 

prior to operation.

WARNING: Fuels used in gas or oil-fired appliances, and the 

products of combustion of such fuels, contain chemicals known to 

the State of California to cause cancer, birth defects, and/or other 

reproductive harm. This warning is issued pursuant to California 

Health & Safety Code Sec. 25249.6.  
While this appliance is not in use, the gas must be turned off at 

the gas supply.
DO NOT ATTEMPT TO DISCONNECT THE GAS OR ANY GAS 

FITTING WHILE THIS APPLIANCE IS IN OPERATION.
NEVER leave the decorative gas log set unattended while in 

operation.
NEVER allow children to operate this decorative gas log set.

NEVER place hands or fingers on the front edge of this decora

-

tive gas log set.
NEVER use liquid propane gas in a natural gas unit, or natural 

gas in a liquid propane unit.

DO NOT use solid-fuel or lighter fluid in any decorative gas log 

set.

Any safety screen or guard removed for servicing an appliance 

must be replaced prior to operating the appliance.

During manufacturing, fabrication, and shipping, various com-

ponents of this appliance are treated with certain oils, films, or 

bonding agents. These chemicals ARE NOT harmful, but may 

produce annoying smoke and smells, as they are burned off, 

during the initial operation of the appliance. This may possibly 

cause headaches, and eye or lung irritation. This is a normal 

and temporary occurrence. The initial break-in period should 

last three to four hours. During this period, provide maximum 

ventilation by opening a window or door, to allow odors to dis-

sipate. Any odor remaining after this initial break-in period, will 

be slight and will disappear with continued use.

PROPER CLEARANCES FROM COMBUSTIBLE CON-

STRUCTION AND MATERIALS MUST BE MAINTAINED 

FROM ALL SIDES, TOP, AND BOTTOM OF THIS APPLI-

ANCE.
THIS APPLIANCE SHOULD NEVER BE PLACED NEAR ANY 

COMBUSTIBLE SURFACE.
THIS APPLIANCE SHOULD NEVER BE PLACED UNDER 

ANY COMBUSTIBLE CONSTRUCTION OR MATERIALS.
NEVER PLACE ANY COMBUSTIBLE MATERIAL WITHIN 

TWENTY-FOUR INCHES (24”)FROM THE FRONT OF THE 

FIREPLACE ENCLOSURE.

WARNING 

The damper clamp must be installed in a manner which will 

maintain the minimum permanent damper vent opening at all 

times. 

See Figure 1

Figure 1

WARNING

The State of Massachusetts requires that the chimney flue 

damper, when used with decorative gas log sets, be welded open 

or completely removed. In the Commonwealth of Massachusetts, 

this appliance must be installed by a licensed plumber or gasfit

-

ter.

WARNING

Improper installation, adjustment, alteration, service or mainte-

nance, can cause property damage, personal injury or loss of life. 

Refer to the owner’s information manual, provided with this ap-

pliance. Installation and service must be performed by a qualified 

installer, service agency or the gas supplier.

Summary of Contents for FIAMMA BX18MTN-1

Page 1: ...to substances in fuel or from fuel combustion which can cause death or serious illness WARNING This appliance must be installed only in a solid fuel burning fireplace with a working flue and construc...

Page 2: ...FICATIONS 6 INSTALLATION 7 11 FINAL SET UP 12 LIGHTING INSTRUCTIONS MATCH THROW UNITS 13 LIGHTING INSTRUCTIONS SAFETY PILOT UNITS 14 OPERATION 15 MAINTENANCE SERVICE 16 TROUBLESHOOTING 17 PARTS LIST 1...

Page 3: ...e and draperies Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition Young children should be carefully supervised...

Page 4: ...nitial operation of the appliance This may possibly cause headaches and eye or lung irritation This is a normal and temporary occurrence The initial break in period should last three to four hours Dur...

Page 5: ...alls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a closed area and the odor intensity could v...

Page 6: ...IMENSIONS MASONRY BUILT FIREPLACES Chimney Height Minimum of 6 Feet LOG SET SIZE FRONT WIDTH IN INCHES DEPTH IN INCHES HEIGHT IN INCHES MINIMUM VENT IN SQ INCHES 18 28 16 18 49 24 30 16 18 71 30 36 18...

Page 7: ...appliance see the specifications beginning on page 6 of this manual IMPORTANT This appliance when first installed may produce unpleasant odors these will gradually diminish IMPORTANT Decorative Gas Lo...

Page 8: ...the brass fitting on the burner CAUTION Make sure all gas connections are snug but DO NOT over tighten 6 CHECK FOR LEAKS Apply soapy water to each connection and watch for bubbles If bubbles are seen...

Page 9: ...at there are no leaks Proceed to FINAL SET UP on page 12 WARNING DO NOT use sand in Liquid Propane Hearth Kits Use the Vermiculite provided with the Liquid Propane Change Kit FOR UNITS WITH REMOTE SYS...

Page 10: ...s on programming the coding switches on both transmitter and receiver Figure 11 Hand Held Remote Receiver Front View Figure 12 Hand Held Remote Receiver Rear View Figure 13 Hand Head Remote Receiver T...

Page 11: ...both transmitter and receiver Figure 14 Wall Mount Variable Flame Remote Receiver Front View Figure 15 Wall Mount Variable Flame Remote Receiver Rear View Figure 16 Wall Mount Variable Flame Remote Re...

Page 12: ...ual DO NOT apply extra material not supplied with this appliance All previously applied loose material em bers must be removed prior to reapplication CAUTION DO NOT place glowing embers sand vermiculi...

Page 13: ...as Match Throw Units can be lit by long hearth match hand fire starter or book match clip extender inserted near the center of the burner system 1 STOP Read the safety information above 2 Read all war...

Page 14: ...ove 2 Read all warnings and safety information in this manual WARNING BE SURE THAT THE CHIMNEY DAMPER IS FULLY OPEN 3 Push in the gas control knob slightly and turn it in a clockwise direction to the...

Page 15: ...place when this appliance is in operation Unless other provisions for combustion air are provided the screen shall have an opening s for introduction of combustion air WARNING When this decorative gas...

Page 16: ...in chimney and or vents and clean if necessary 4 Inspect the pilot and burners if applicable The burner system has been adjusted for proper operation at the factory No adjustment is necessary other t...

Page 17: ...ressure Check gas supply pressure Faulty valve Replace valve Faulty pilot or thermocouple Replace Safety pilot Clogged or dirty burner ports Clean burner ports Burner pilot light but will not stay on...

Page 18: ...FG10086 LAVA ROCK 5 FG10010 FG10010 FG10010 FG10010 DAMPER CLAMP 6 FG10020 FG10020 FG10020 FG10020 ORIFICE MT BRASS ELBOW 375 M X 375 M 50 20 TAP 7 FG10400 FG10292 FG10292 FG10292 ORIFICE 8 FG10065 F...

Page 19: ...FG10239 1 0214 Page 19 PARTS VIEW...

Page 20: ...ranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Numb...

Page 21: ...s option Duties of the Owner The appliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the ap pliance A bill of sale cancelled check or...

Page 22: ...FG10239 1 0214 Page 22 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Page 23: ...FG10239 1 0214 Page 23 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Page 24: ...ms Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Reviews: