background image

37001-5-0220

Page 2

Empire Comfort Systems Inc. • Belleville, IL

3.  Remove burner base.

 See Figure 7.

Figure 7

4.  Remove Blower Access Plates by taking out (6) screws 

each. 

See Figure 8.

Figure 8

5.  Place Blower onto blower brackets. 

See Figure 9.

Figure 9

6.  Hand bend tab as shown in

 Figure 10 

and secure with 

(2) screws.

HAND BEND

TAB INWARD

HAND BEND

TAB INWARD

Figure 10

7.   Remove protective connectors on Wire Assembly from 

fireplace and discard. Connect Wire Harness to both blowers 

and the other end to the Wire Assembly supplied with the 

fireplace. 

See Figure 11.

TO WIRE ASSEMBLY

(MODULE)

Figure 11

8.  Replace Blower Access Plates with (6) screws each.

 

See Figure 12.

Figure 12

9.  Replace burner base and burners removed in steps 2 and 3. 

See Figures 6 and 7. 

10.  Replace Screen Barrier, Glass Frame, and liners removed in  

Step 1. 

See

 

Figure 5.

DVCT40 SHOWN

Reviews: