background image

40652-0-0719

Page 6

MULTIFUNCTION REMOTE OPERATING INSTRUCTIONS

The Thermostat Feature may be disabled if desired.

With all three AAA type batteries installed:

1.   Take out one AAA battery.

2.   While re-inserting the AAA battery, Push and hold down the 

thermostat button. This will disable the thermostat feature on 

the transmitter.

Room Thermostat (Transmitter Operation)

The Remote Control can operate as a room thermostat. The 

thermostat can be set to a desired temperature to control the 

comfort level in a room. To activate this function, press the Ther-

mostat Button. 

See Figure 3

. The LCD display on the Transmitter 

will change to show that the room thermostat is “oN” and the 

set temperature is now displayed. 

See Figure 14.

 To adjust the 

set temperature, press the Up or Down Arrow Buttons until the 

desired set temperature is displayed on the LCD screen of the 

Transmitter. 

See Figure 15.

SET TEMPERATURE

ROOM TEMPER ATURE

Figure 14

Figure 15

Smart Thermostat (Transmitter Operation)

The Smart Thermostat function adjusts the flame height in 

accordance to the difference between the set point temperature 

and the actual room temperatures. As the room temperature gets 

closer to the set point the Smart Function will modulate the flame 

down. To activate this function, press the Thermostat Button until 

the word “SmART” appears to the right of the temperature bulb 

graphic. 

See Figure 16

. To adjust the set temperature, press the 

Up or Down Arrow Buttons until the desired set temperature is 

displayed on the LCD screen of the Transmitter. 

See Figure 17.

NOTE

: When Smart Thermostat is activated, manual flame 

height adjustment is disabled.

Figure 16

Figure 17

Blower Control (Fan)

If the appliance is equipped with a hot air circulating fan, the 

speed of the fan can be controlled by the Proflame system. The 

fan speed can be adjusted through six speeds. To activate this 

function, use the mode Button 

Figure 3

 to index the fan control 

icon. 

See Figure 18

. Use the Up/Down Arrow Buttons 

Figure 

56

 to turn on off or adjust the fan speed. 

See Figure 19

. A single 

“beep” will confirm reception of the command.

OFF

Figure 18

OFF

Figure 19

Summary of Contents for DVCT40CSP-OUT

Page 1: ...nity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be perf...

Page 2: ... to the fireplace This is a heating appliance The flow of heat can ignite combustibles Figure 1 GENERIC MODEL SHOWN COMBUSTIBLE MATERIAL TABLE OF CONTENTS SECTION PAGE Multifunction Remote Operating Instructions 3 9 Lighting Instructions 10 Maintenance And Service 11 12 Important Safety Information 13 Safety Information For Users Of Propane Gas 14 Requirements For Massachusetts 15 Warranty 16 ...

Page 3: ...rner when operating the remote system or activating manual bypass of the remote system CAUTION Property Damage Hazard Excessive heat can cause property damage The appliance can stay lit for many hours Turn off the appliance if it is not going to be attended for any length of time Always place the Transmitter where children can not reach it Figure 3 NOTE This control system includes a Battery Back ...

Page 4: ...with a paper clip and the IFC module will beep three times to indicate the IFC module is ready to synchronize with the transmitter within ten seconds See Figure 5 Figure 4 SWI BUTTON Figure 5 5 With the batteries already installed in the Transmitter push the On button The Receiver will beep four times to indicate the Transmitter s command is accepted and sets to the par ticular code of that Transm...

Page 5: ...m the Receiver confirms reception of the command Remote Control Display Figure 9 Remote Flame Control The Proflame has six flame levels With the system on and the flame level at the maximum in the appliance pressing the Down Arrow Button once will reduce the flame height by one step until the flame is turned off The Up Arrow Button will increase the flame height each time it is pressed If the Up A...

Page 6: ... Transmitter Operation The Smart Thermostat function adjusts the flame height in accordance to the difference between the set point temperature and the actual room temperatures As the room temperature gets closer to the set point the Smart Function will modulate the flame down To activate this function press the Thermostat Button until the word SMART appears to the right of the temperature bulb gr...

Page 7: ...plit Flow To activate this function use the Mode Button Figure 3 to index to the SPLIT FLOW mode icon See Figures 22 and 23 Pressing the Up Arrow Button will activate the secondary burner Pressing the Down Arrow Button will turn the secondary burner off A single beep will confirm the reception of the command OFF Figure 22 MULTIFUNCTION REMOTE OPERATING INSTRUCTIONS OFF Figure 23 Remote Auxiliary R...

Page 8: ... to avoid unsupervised operation To activate this function press the MODE and UP Buttons at the same time See Figure 28 To deactivate this function press the MODE and UP Buttons at the same time OFF Figure 28 Low Battery Power Detection Transmitter The life span of the remote control batteries depends on various factors quality of the batteries used the number of ignitions of the appliance the num...

Page 9: ... the wall control or remote control OFF for two or three seconds and then restoring a power supply back on The return of the system to normal operation must be checked under safe conditions by the user and or service personnel Using the Fireplace without a Remote Control The fireplace can be turned ON HI only and OFF with the wall switch The fireplace flame ON OFF is the only function that will op...

Page 10: ...HTING INSTRUCTIONS 1 STOP Read the safety information above 2 Turn OFF electric power to the appliance 3 Turn gas shut off knob counterclockwise to ON position 4 Wait ten minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above on this label If you do not smell gas go to the next step 5 Turn ON electric power to the app...

Page 11: ...nd at least annually Inspect the external vent cap on a regular basis to make sure no debris is interferes with the air flow Cleaning the Glass Clean the glass periodically We recommend gas fireplace glass cleaner During start up condensation forms on the inside of the glass causing lint dust and other airborne particles to cling to the glass Also initial paint curing may deposit a film on the gla...

Page 12: ...Places LAT CH Glass Latch Tool LAT CH L A T C H Figure 31 Light Bulb s Replacement 1 Remove the following items barrier screen glass frame assembly This unit comes standard with two lights that are attached to the roof of the fireplace To access the light bulb you will remove the following items by removing four screws per light See Figure 32 metal bezel glass gasket NOTE Use gloves when handling ...

Page 13: ...objects on or around the fireplace that may restrict air flow Keep the area around the fireplace free of combustible materials including drapery upholstered furniture paper boxes and clothing Never hang stockings or cards above the fireplace Never operate the fireplace with the glass front removed or damaged Any part removed for cleaning or servicing must be replaced prior to operating the firepla...

Page 14: ...ed gas can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity Propane Gas may stratify in a closed area and the odor intensity could vary at different levels Since it is heavier than air theremaybemoreodoratlowerlevels Alwaysbesensitive to the slightest gas odor If you detect any odor t...

Page 15: ...20 and be ANSI UL 2034 listed and IAS certified 3 SIGNAGE A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating fireplace or equipment The sign shall read in print size no less than 1 2 inch in size GAS VENT DIRE...

Page 16: ...the instructions furnished with the appliance A bill of sale canceled check or payment record should be kept to verify purchase date and establish warranty period Ready access to the appliance for service What Is Not Covered Damages that might result from the use misuse or improper installation of this appliance Travel diagnostic costs and freight charges on warranted parts to and from the factory...

Reviews: